Mitsubishi Electric GOT2000 Series User Manual page 214

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■12. Depth dimensions for the GOT with several extension units mounted in multiple stages
(GT27, GT25)
The following shows how to calculate the depth dimensions for the GOT with several extension units mounted in
multiple stages.
For the dimensions for the GOT with one extension unit, refer to the dimension D in .
Step 1.
Select the GOT main unit coefficient from the following table.
GT27, GT25
Step 2.
Select the option coefficient of the extension unit from the following table.
*1*2
GT27-V4-Z
GT15-QBUS, GT15-QBUS2, GT15-RS2-9P, GT15-RS4-9S, GT15-RS4-TE,
GT15-J71LP23-25, GT15-J71BR13, GT15-J61BT13, GT15-PRN, GT15-DIO,
GT15-DIOR, GT15-SOUT
GT27-MMR-Z
GT15-J71GP23-SX
*1
*2
Step 3.
Substitute the coefficients selected in step 1 and step 2 to the following formula.
E (for two extension units) = G (GOT main unit coefficient) + H (option coefficient) + H (option coefficient)
F (for three extension units) = G (GOT main unit coefficient) + H (option coefficient) + H (option coefficient)
+ H (option coefficient)
Calculation example:
Dimension F (for three extension units) for installing the multimedia unit (GT27-MMR-Z) in the first stage
and the second stage,and the CC-Link IE Controller Network communication unit (GT15-J71GP23-SX) in
the third stage on the GT2712
F (for three extension units) = -3.5 (main unit coefficient of GT2712) + 57.0(option coefficient of GT27-MMR-
Z) + 35.5 (option coefficient of GT15-J71GP23-SX) = 89.0
When the above two extension units are installed, the dimension F is 89.0 mm.
11 - 18
11.1 External Dimension Diagrams
E
F
GOT type
*1*2
, GT27-R2-Z
, GT27-V4R1-Z
*1*2
*1
, GT15-J71GF13-T2
Mounting GT27-V4-Z, GT27-R2-Z, GT27-V4R1-Z, GT27-ROUT-Z, or GT27-MMR-Z requires two stages. When mounting GT15-
J71GP23-SX or GT15-J71GF13-T2 on any of the above units, mount it in the third stage.
The extension unit cannot be used on GT2705, GT2512, GT2510, or GT2508.
100 (3.94)or more
Other device
Unit: mm (inch)
G (main unit coefficient)
1.5(0.06)
Model
*1*2
*1*2
, GT27-ROUT-Z
*1
H (option
coefficient)
43.0(1.69)
21.5(0.85)
57.0(2.24)
35.5(1.40)