Value Range
Other, 60 %, 67 %
Maintenance Console Location
2.7.10 [1-1] Slot—LCO Card Property
Programming Manual References
2.7.11 [1-1] Slot—LCO Port
Feature Manual References
None
Low Speed Pulse Dial—Break Width
Specifies the maximum length of the break signal in a low speed pulse dial. Low Speed Pulse Dial—
Pulse % Break on this screen determines the value that can be specified here.
Default
60 ms
Value Range
4 × n (n=6–20) ms
Maintenance Console Location
2.7.10 [1-1] Slot—LCO Card Property
Programming Manual References
2.7.11 [1-1] Slot—LCO Port
Feature Manual References
None
Low Speed Pulse Dial—Make Width
Specifies the minimum length of the make signal in a low speed pulse dial. Low Speed Pulse Dial—
Pulse % Break on this screen determines the value that can be specified here.
Default
40 ms
Value Range
4 × n (n=3–15) ms
Maintenance Console Location
2.7.10 [1-1] Slot—LCO Card Property
Programming Manual References
2.7.11 [1-1] Slot—LCO Port
2.7 [1] Configuration
PC Programming Manual
111