TimerControl
This section describes TimerControl category for the BG series.
This camera series is able to generate Timer0Active signal, derived from exposure start, by register setting.
This signal can be used as strobe control signal.
EXPOSURE ACTIVE
● Registers
Register
Visibility
TimerSelector
Expert
TimerDuration
Expert
TimerDelay
Expert
TimerTriggerSource
Expert
● Setting
- Set the width of Timer0Active pulse
Set the following value to "TimerDuration" register. Setting value is Float type.
Copyright © 2014 TOSHIBA TELI CORPORATION, All rights reserved.
EXT_TRIG
Exposure
TIMER0 ACTIVE
Fig.5-10 Timer0Active
Access
R
Returns the name of the timer that selected.
R/W
Sets the width of Timer0Active signal.
R/W
Sets the delay of Timer0Active signal.
R
Returns the timing that is the basic of the timer
Pulse width
Minimun (*)
Maximum
Delay
Duration
Description
Value
0.00[μs]
2000000.00[μs]
* initial factory setting
55 / 80
* ActiveLow
D4235067D
http://www.toshiba-teli.co.jp/index.htm