c) SCAN TEST
This test mode is used for checking document scanning section.
1) Press [SET] + [MENU].
(over 1sec.)
(Refer to 6-3-(l))
l: INITIAL
SET
?
2) Press [MENU] twice or just press [3].
3:
SCAN
TEST
?
3) Press [SET].
4) Press [COPY] to complete.
A shading signal waveform
is memorized
then, goes to
next test mode "MODEM TEST".
**
SCAN
TEST'
**
4: MODEM
TEST
?
d) MODEM TEST
This test mode is used for checking or measuring
output signals
from modem.
1) Press [SET] + [MENU].
(over 1sec.)
—.
(Refer to 6-3-(l))
l:
INITIAL
SET
?
2) Press [MENU] 3-times or just press [4].
4: MODEM
TEST
?
3) Press [SET].
* Press [START] to call for the next signal.
* Press [COPY] to call for the previous signal.
I
9600
BPS
(0)
]
SIGNAL ORDER :
9600 BPS (0)
7200 BPS (0) ~ 4800 BPS (0) ~ 2400 BPS *
300 BPS (0)
1
~
21OOHZ
1100Hz
PB8
NO SIGNAL
RETURN TO 9600BPS (0)
The signals of 9600, 7200, 4800, 2400 and 300 BPS can be changed its carrier frequency
and pattern as shown below.
Press [Rx. MODE] to change its pattern at each stage.
(0)
: 1850Hz continuously
(1)
: 1650Hz continuously
(1:1 ) : 1650/1850Hz
alternately
(3.3ms/3.3ms)
(1 :4) : 1650/1850Hz
alternately
(3.3ms/13.2ms)
=
time is a case of 300 BPS
(4:1) : 1650/1850Hz
alternately
(13.2 ms/3.3ms)
* Press [SPEAKER].
MONITOR
SPEAKER
is activated.
* Press number key when display shows "PB8", DTMF signal corresponding
to the
number key is generated.
.-
4) Press [STOP/C] to finish