Setting items
Setting No.
Contents
Fact. set
Explanation
69
TCF check interval
V29
V27
00
5ms
115ms
00
Set the time from the recognition of the
01
60ms
170ms
training by the Modem to starting the training
02
100ms
210ms
check(TCF).
Set to correct the mismatching
of between SANYO
and other Mfr's machine.
70
FSK check before
00
OFF
When this unit can not receive the high speed
phase-C
01
ON
01
training signal by the echo of CFR (E-52), set
to OFF (SETTING
No.
00).
71
Allowance of Error lines
00
32
When receiving consecutive
error lines
01
64
01
exceeding the setting number, the nit moves
02
96
to the sequence of bad copy quality and send
03
128
RTN to transmitter.
04
160
When the E-30 occurs frequently,
set the
05
192
number to higher value but printing quality is
06
224
getting worse.
07
256
08
No limit
74
Carrier OFF detection
00
0 sec.
duration
This is to set the allowance of the carrier off
01
0.5 sec.
duration.
02
1.0 sec.
If the carrier off duration is less than the
03
1.5 sec.
setting value, reception is continued.
04
2.0 sec.
05
2.5 sec.
06
3.0 sec.
06
1
+0.5 sec. step.
12
6.0 sec.
75
Transmission
start
00
2400BPS
This is to set the training start speed of the
speed
01
4800BPS
MODEM,
02
7200 BPS
It is recommended
that if Tx. error occurs
03
9600BPS
03
frequently set to 4800BPS.
76
TSI
01
Transmit in
This is to set the condition of transmitting
TSI.
anycase
02
Transmit only
02
when CSI
receives
77
DCS timing
00
Response to the
00
This is to set the response of DCS
first DIS
corresponding
to DIS.
01
Response to the
In order to consider the influence of the echo
second DIS
while transmitting
to overseas fax.
2nd DIS (SETTING No. Ol)might
be effective.
78
Interval between DCS
00
75 ms
00
This is to set the interval between DCS and
and Training
01
0.3 sec.
training for the purpose of correcting the
02
0.5 sec.
mismatching
of between SANYO and other
manufacture's
machine.
ITU-T recommendation
is 75 + 20 ms.
79
Interval between RTC
00
75 ms
00
This is to set the interval between RTC and Q
and Q
01
0.3 sec.
for the purpose of correcting the mismatching
02
0.5 sec.
of between SANYO and other manufacture's
machine.
ITU-T recommendation
is 75 ~ 20 ms.
80
Document jam
00
1.5m
00
This selection defines the original length the
01
3.0 m
SFX-33 can accept.
02
No limit