1.2 Self-Diagnosis Modes

Input
Mode
code
All-LEDs-lit
"01"
Aging mode
"02"
Test mode
"03"
Test print
"04"
mode
Adjustment
"05"
mode
Aging mode
"07"
Setting mode
"08"
Note:
To access the desired diagnostic mode, turn on the power switch while pressing the appropriate keys.
<Procedure>
• All-LEDs-lit mode (01):
0
1
All LEDs light
PWR
• Aging mode (02 or 07):
0
2
0
PWR
PWR
• Test mode (03): Refer to 1.2.1 and 1.2.2.
• Test print mode (04): Refer to "1.2.3 Test print mode".
• Adjustment mode (05): Refer to "1.2.4 Adjustment mode".
• Setting mode (08): Refer to "1.2.5 Setting mode".
Notes: C/S: Press the CLEAR/STOP key
PWR: Turn on the power switch
INT:
Press the INTERRUPT key
E/S: Press the ENERGY SAVER key
2460 ADJUSTMENT
Definition
All LEDs on the control panel are lit.
Aging (RADF does not operate)
Motor test and input/output check
Test print
Adjustment of items
Aging (includes RADF)
System switchover and setting of each
priority mode, PM counter, etc.
START
START
7
Aging
START
Cleaning
method
C/S
"09"
"09"
"09"
"09"
"09"
"09"
Key check
C/S
0
9
C/S
1 - 4
September 1997 © TOSHIBA CORP.
Display after selection
AGING MODE
100%
TEST MODE
100%
TEST PRINT MODE
100%
TEST MODE
100%
AGING MODE 2
100%
TEST MODE
100%
Exit
Exit