MULTI-CELL SYSTEM SETUP
1-24
3. In the left hand panel, click on Multi cell. This opens the Multi-cell
screen.
Figure 1-18 Multi-cell Screen (Default Values)
4. Set the Multi cell system field to Enable.
5. In the System chain ID field, enter the unique identifier of the chain
this base station should belong to. ID values are 0 to 99999.
Note:
Do not use the default value 512 for multicell systems.
6. In the Synchronization time(s), change the number of seconds
between each time this base station re-synchronizes with the other
base stations in this chain (if necessary).
7. If you want the base station to log low level multi cell debug
information in the System Log, set the Multi cell debug field to Data
Sync, Auto Tree, or Both. (This log contains a large number of
messages, so you should leave it disabled most of the time.)
8. Click Save, then reboot the base station (go back to the Home/Status
screen and click Reboot).
9. When the base station finishes rebooting, verify that the RFPI-
Address on the Home/status screen shows RPN:00 at the end of the
field. After a few minutes, the System Information field also updates
to display the new status.
Figure 1-19 Home/Status Screen (Primary Base Enabled)