Motorola APX 7000 Detailed Service Manual page 139

Hide thumbs Also See for APX 7000:
Table of Contents

Advertisement

Troubleshooting Charts: RX RF Failure
RX RF Failure – Page 3
2
Remove shield, SH4.
Measure RF levels at first
preselector filter and
compute filter loss.
VHF: Input side of C301 &
output side of C307.
Loss < 2 dB?
Yes
Measure RF levels at LNA and
compute LNA gain.
UHF1/VHF and VHF / 7/800:
Input side of C311 & output side of R307.
UHF2/VHF: Input side of C311 &
output side of C329.
Gain about
18 dB?
Yes
Measure RF levels at second
preselector filter and compute
filter loss.
VHF: input side of C318 & output
side of C326.
Loss < 6 dB?
Yes
Measure RF levels of the RF
switch, U501, at the input to the
mixer and compute loss.
VHF: output side of C502 and
input side of C511.
U501 loss
< 1 dB?
Yes
8
Note: RF Test frequency used:
VHF: 154.275 MHz
UHF1: 424.975 MHz
UHF2: 485.075 MHz
700: 769.0625 MHz
800: 860.0625 MHz
Measured with a high impedance probe for relative comparisons and troubleshooting only.
Actual S21 gain or loss may differ if the test point is not 50 ohms.
Check components
No
and replace defective
parts.
No
Check components
No
and replace defective
parts.
Check digital logic
to the RF switch
No
and replace U501 if
needed.
Check LNA:
Check DC bias voltages of
U302 at the base (pin 1) &
collector (pin 3).
Is base voltage =
0.796 V? Collector
voltage = 1.563 V?
Yes
Check DC bias voltages of
Q302 at the base (pin 2 or
5), collector (pin 3) & emitter
(pin 4).
Is base voltage = 1.017
V? Collector voltage =
0.796 V? Emitter
voltage = 1.566 V?
Yes
Check DC input line voltages
and visually inspect and
replace defective
components if needed.
5-35
No
Replace
U302
No
Replace
Q302

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apx 7000xe

Table of Contents