Procedure 11: Configuring the T1 ports using the CLI

Follow this procedure to configure the T1 ports from the CLI manager.
Action
Log in
Set T1 line length
Set T1 line code
 
Issue 3
 
 
 
 
 
Press Enter.
At the username prompt, enter admin.
At the password prompt, enter password.
NOTE: If the incorrect line length is selected, the result could be decreased
T1 quality or echo on voice lines. The default length is 133 ft.
Enter
set line [1/2/3/4] length [133, 266, 399, 533]
where
[1/2/3/4] represents T1 ports 1 through 4.
[133, 266, 399, 533, 655] represents line length in feet.
RESULT: The system responds
Line [1/2/3/4] length
dB; 266-399 / 1.8 dB; 399-533 / 2.4 dB; 533-655 / 3.0
dB]
NOTE: If the line code does not match the incoming T1 settings, then Bipolar
Violations (BPVs) will occur. The default code is B8ZS.
Enter set line [1/2/3/4] code [B8ZS/AMI]
where
[1/2/3/4] represents T1 ports 1 through 4.
[B8ZS/AMI] represents the line coding scheme.
RESULT: The system responds
Line [1/2/3/4] code [B8ZS/AMI]