Teléfonos inalámbricos Contenido y precauciones de seguridad Controles de operación FT-8859 Procedimientos de alineamiento Diagrama a bloques Diagramas esquemáticos Procedimiento de localización de fallas Carta de voltajes de transistores y de IC Identificación de terminales de semiconductores Localización de partes eléctricas Diagramas de conexiones (alambrado) Vistas explotadas y lista de partes mecánicas...
Page 2
FILE NO. 2B0-9907 SERVICE MANUAL CORDLESS TELEPHONE FT-8859 PUBLISHED IN JAPAN, Oct., 1999...
ALIGNMENT PROCEDURE Test Mode For Base Unit Press the " " and "#" keys at the same time about 2 seconds while turning the power on, the confirmation beep will sound to indicate that the unit is in the test mode. 1.
Page 6
Test Mode For Handset Unit 7R#SHUIRUP#WKH#7(67#PRGH/#WXUQ#WKH#SRZHU#21#E\#SUHVVLQJ#WKH#³ ´#DQG#³&´#EXWWRQV#DW#WKH#VDPH#WLPH1 When entered the TEST mode, the bell rings and the unit enters TEST mode 1. (Refer to the following table.) 1. To change the TEST mode: Press the number key for the corresponding TEST mode. (Refer to the following table) 2.
Page 7
Base Unit Transmitter Section AF GEN. BASE Unit Power Test Point Connections Dummy Load Meter (600-ohm) DC IN TEL Line 9V Jack Jack 1kHz 77.6mV Test Point Frequency Counter AC 120V Adapter 60Hz Deviation Meter Preset Place the Base unit in VCO/TX FREQ. ADJ mode in accordance with the procedure on page 3. Alignment Procedure step Adjutment...
Page 8
Receiver Section Connections BASE Unit AC Voltmeter RF SG Dummy Load (600-ohm) TEL Line Test Point Jack DC Voltmeter Terminal DC IN 9V Jack AC 120V 60Hz Adapter Preset Place the Base unit in RX SENS mode (step 4) in accordance with the procedure on page 3. Alignment Procedure step Preset to...
Page 9
Handset Unit Transmitter Section Connection HANDSET Unit AF GEN. Test Point Power Meter J603 Battery 1kHz 9mV MIC+Pin Connector Test Point Frequency Counter DC Power Supply Deviation Meter DC 3.8V Preset a) Connect the handseet RF unit to the handset main unit. b) Connect DC power supply to battery connector on the handset unit.
Page 10
Receiver Section Connection HANDSET Unit AC Voltmeter RF SG Dummy Load (150-ohm) Test Point Connector DC Power Supply J603 DC Voltmeter Terminal Battery Connector DC 3.8V Preset a) Connect the handset RF unit to the handset main unit. b) Connect DC power supply to battery connector on the handset unit. c) Turn the DC power supply ON while pressing “...
TROUBLESHOOTING HINTS 1. The bell does not ring. When the INTCOM key of See 2. The bell does not the base is pressed, does ring & page does not ring. the ringer on the handset ring? When the TEL SG is joined Check IC4 and TEL with the base to make bell network circuit.
Page 17
2. The bell does not ring & page does not ring. Can the base and handset See 3. The base and handset be connected. cannot be connected. Press handset DIAL key When Check IC603. while in TALK MODE. handset is pressed, can the Can key touch sound be pulse output at pin 58 of heard from the ringer?
Page 18
3. The base and handset cannot be connected. Check whether the base is Check IC22 and its peripheral able to set in the test mode circuit. Check the TX POWER and Check base RF unit. the TX FREQUENCY on the base unit. Set the base in the test Check RT3, C234, R58 and Check whether there is a...
Page 19
Set the handset in the test Check whether there is a Check R634, R635, R636, mode 3, check whether 250 Hz data waveform at R632, R619, C610, C669 deviation of the TX data is C669. and RT603. app. 8 kHz Dev. Check handset RF unit.
Page 20
4. Will not dial out. (TONE) Check IC22, Q20 and their Check whether there is a peripheral circuits. DTMF waveform on Pin 60 of IC22. Check IC3, Q20 and their Check whether there is a peripheral circuits. DTMF waveform on Pin7 of IC3.
Page 21
5. TROUBLE WITH INTERCOM MODE 5-1. The voice from the Base unit cannot be heard on the Handset. Check whether there is an Check MC1 and IC32. audio waveform on Pin 4 of IC32. Check Pin 7 of IC32. 5-2. The voice from the Handset cannot be heard on the Base unit. Check whether there is an Check IC15.
Page 22
6. TROUBLE WITH SPEAKERPHONE MODE 6-1. The voice of the caller cannot be heard (INCOMING CALL). Check whether there is an Check IC3, RL1 and Q2. audio waveform on Pin 1 of IC3. Check whether there is an Check IC15. audio waveform on Pin 1 of IC15.
IC AND TRANSISTOR VOLTAGE CHART Base Unit Unit[V] Unit[V] Ref No. PIN STBY TALK NOTE Ref No. PIN STBY TALK NOTE 4.0-5.5 3.6-5.1 CLK(SIN) 3.9-4.0 3.5-4.4 CLK(SIN) 3.6-4.1 --/(PULSE) 3.6-4.1 --/(SIN) IC11 1.2-2.5 1.4-1.9 0.4-1.0 IC15 OPEN OPEN 0.1-4.7 0.1-4.4 (PULSE) IC18 OPEN...
Page 24
Unit[V] Unit[V] Ref No. PIN STBY TALK NOTE Ref No. PIN STBY TALK NOTE 0.0-4.9 0.0-4.6 CLK(SIN) 1.1-3.0 1.0-2.9 CLK(SIN) VCPU OPEN OPEN IC22 OPEN OPEN OPEN VCPU VCPU VCPU OPEN IC23 OPEN OPEN 4.8/0.0 0.0/0.0 TONE/PULSE IC22 4.8/0.0 4.5/0.0 RING0N/OFF OPEN 0.06-0.1...
PARTS LIST PRODUCT SAFETY NOTE : Products marked with a have special characteristics important to safety. Before replacing any of these components, read carefully the product safety notice of this service manual. Don't degrade the safety of the product through important servicing. Symbol Symbol ±...
Page 40
LOC. REF. PART NO. DESCRIPTION RC001811 BCAZ901016Z ELECTROLYTIC 100UF 6.3V M C-156 RC005202 BCML311045Z CERAMIC M/L (1608) TAPE 0.1UF 16V K B RC005205 BCML811035Z CERAMIC M/L (1608) TAPE 0.01UF 50V K B C102 RC001805 BCAZ811096Z ELECTROLYTIC 1UF 50V M C-156 C103 RC001794 BCAZ111016Z...
Page 41
LOC. REF. PART NO. DESCRIPTION C194 RC001805 BCAZ811096Z ELECTROLYTIC 1UF 50V M C-156 C195 RC005202 BCML311045Z CERAMIC M/L (1608) TAPE 0.1UF 16V K B C196 RC008731 BCXK311050Z CERAMIC M/L (2125) TAPE 1UF 16V Z F C197 RC005202 BCML311045Z CERAMIC M/L (1608) TAPE 0.1UF 16V K B C198 RC001805...
LOC. REF. PART NO. DESCRIPTION RC008783 VNYL2304060 VINYL BAG 300x400x600x0.07T RC008353 VNYL3101000 VINYL BAG 100x100x0.1T RC008423 VNYL3102500 VINYL BAG 100x250x0.1T ASSEMBLY PARTS LIST LOC. REF. PART NO. DESCRIPTION RC008637 AC229BLBA BASE MAIN PCB ASSEMBLY RC008638 AC229BLBC BASE KEY PCB ASSEMBLY RC008639 AC229BLPA HANDSET MAIN PCB ASSEMBLY...