ALIGNMENT PROCEDURE Base Unit Transmitter Section BASE Unit AF GEN. Test Point Power Meter Connections DC IN TEL Line 1kHz -20dBm 9V Jack Jack Test Point Frequency Counter AC 120V Adapter 60Hz Deviation Mater Preset a) Connect the base RF unit to the base main unit. b) Set the “TONE / PULSE”...
Page 5
Receiver Section Connections BASE Unit AC Voltmeter RF SG Dummy Load (600-ohm) TEL Line Test Point Jack DC Voltmeter DC IN 9V Jack Terminal AC 120V 60Hz Adapter Preset a) Connect the base RF unit to the base main unit. b) Set the “TONE/PULSE”...
Page 6
Handset Unit Transmitter Section Connection HANDSET Unit AF GEN. Test Point Power Meter J603 Battery 1kHz 9mV MIC+Pin Connector Test Point Frequency Counter DC Power Supply Deviation Mater DC 3.8V Preset a) Connect the handseet RF unit to the handset main unit. b) Connect DC power supply to battery connector on the handset unit.
Page 7
Receiver Section Connections HANDSET Unit AC Voltmeter RF SG Dummy Load (150-ohm) Connector Test Point DC Power Supply J603 DC Voltmeter Battery Terminal Connector DC 3.8V Preset a) Connect the handset RF unit to the handset main unit. b) Connect DC power supply to battery connector on the handset unit. c) Turn the DC power supply ON while pressing “...
TROUBLESHOOTING HINTS 1. The bell does not ring. See 2. The bell does not ring When the PAGE SW of the & page does not ring. base is pressed, does the ringer on the handset ring? When the TEL SG is joined Check IC4 and TEL network with the base to make bell circuit.
Page 13
2. The bell does not ring & page does not ring. Can the base and handset be See 3. The base and handset connected? cannot be connected. Press handset DIAL key When the key of the handset is Check IC603. while in TALK MODE.
Page 14
3. The base and handset cannot be connected. Check whether the base Check IC4 and its is able to set in the test peripheral circuit. mode 1. Check the TX POWER Check base RF unit. and the TX FREQUENCY on the base unit. Press “PAGE”...
Page 15
Press “3” key, check Check whether there is a C h e c k R 6 3 5 , R 6 3 6 , whether deviation of the 250 Hz data waveform at R 6 3 4 , R 6 3 2 , R 6 1 9 , TX data is app.
Page 16
4. Cannot make a phone call (pulse). Can the base and handset See 3. The base and handset be connected? cannot be connected. While in TALK MODE, press Check IC5. dial key of the handset. Check whether square waveform from pin 22 of IC5 is fed.
Page 17
6. Voice cannot be transmitted to other party (outgoing call). Can the base and handset be See 3. The base and handset connected? cannot be connected. The 1 kHz, 9.0mV sine Check Q604 and its wavefor m i s a p p l i e d t o peripheral circuit.
Page 18
7. The voice of the caller cannot be heard (incoming call). Can the base and handset be See 3. The base and handset connected? cannot be connected. The 1 kHz, 77.5mV sine Check the base TEL-line waveform is applied to TEL- circuit and REPLAY control line of the base, can the 1 kHz circuit.
PARTS LIST PRODUCT SAFETY NOTE : Products marked with a have special characteristics important to safety. Before replacing any of these components, read carefully the product safety notice of this service manual. Don't degrade the safety of the product through important servicing. Symbol Symbol ±...
Page 35
LOC. REF. PART NO. DESCRIPTION RC004172 BCXT813925Z CERAMIC M/L (2125) TAPE 0.0039UF 50V K B RC002229 BCXT511045Z CERAMIC M/L (2125) TAPE 0.1UF 25V K B RC003193 BCXT815625Z CERAMIC M/L (2125) TAPE 0.0056UF 50V K B RC008431 BCBH817092Z CERAMIC M/L (2125) TAPE 7PF 50V D CH RC001068 BCXT811025Z CERAMIC M/L (2125) TAPE...
Page 36
LOC. REF. PART NO. DESCRIPTION C607 RC008296 BCSH901006Z TANTALUM CHIP TAPE 10UF 6.3V M C-122 C608 RC005202 BCML311045Z CERAMIC M/L (1608) TAPE 0.1UF 16V K B C609 RC008296 BCSH901006Z TANTALUM CHIP TAPE 10UF 6.3V M C-122 C610 RC005204 BCML811025Z CERAMIC M/L (1608) TAPE 0.001UF 50V K B C611 RC008446 BCSH311096Z TANTALUM CHIP...
100X100X0.1T RC008719 VNYH1103000 VINYL BAG 100X300X0.05T HIPE ASSEMBLY PARTS LIST NOTE: Following part numbers are not available as replacement parts. Order parts necessary for repair or contact the Toshiba Factory Service Center. LOC. REF. PART NO. DESCRIPTION RC008469 AC221ZLBA MAIN PCB ASSEMBLY, BASE...