3-6] Extension Hunting Group - Panasonic KX-TDA50 Pc Programming Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

2.10 [3] Group
Options—Wrap-up Timer based on
Selects whether the ICD Group member wrap-up timer or extension wrap-up timer is used.
If Extension is selected here, Wrap-up Timer on 2.10.13 [3-5-1] Incoming Call Distribution
Group—Member List becomes unavailable. If ICD Group Member is selected, Wrap-up Timer on
2.11.1 [4-1-1] Wired Extension—Extension Settings and 2.11.10 [4-2-1] Portable Station—
Extension Settings become unavailable.
Default
Extension
Value Range
Extension: The timer is activated after all calls to or from the extension, including a retrieved call on
hold.
ICD Group Member: The timer is only activated after calls to the extension through an ICD Group.
Maintenance Console Location
2.10.15 [3-5-3] Incoming Call Distribution Group—Miscellaneous
Programming Manual References
2.10.13 [3-5-1] Incoming Call Distribution Group—Member List—Wrap-up Timer
2.11.1 [4-1-1] Wired Extension—Extension Settings—Option 8—Wrap-up Timer
2.11.10 [4-2-1] Portable Station—Extension Settings—Option 8—Wrap-up Timer
Feature Manual References
1.9.3 ICD Group Features—Log-in/Log-out

2.10.16 [3-6] Extension Hunting Group

If an extension within an idle extension hunting group is called when it is busy or in DND mode, the
call can be redirected to another extension in the same hunting group, according to a preprogrammed
hunting type. If there is no idle extension in the group, the call can then be redirected to the overflow
destination, which can be different depending on the time mode (day/lunch/break/night). A maximum
of 64 (with the KX-TDA50/KX-TDA100/KX-TDA200) or 128 (with the KX-TDA600) hunting groups can
be programmed, each containing up to 16 extensions.
To assign members to the group, click Member List. To assign extensions as overflow destinations
easily, click Destination Setting (see 2.1.6 Extension Number Setting).
Hunting Group Name
Specifies the name of the hunting group.
Default
Not stored.
Value Range
Max. 20 characters