Rated Input; How To Read The Rated Label; A1 Output - Panasonic KT9 Instruction Manual

Hide thumbs Also See for KT9:
Table of Contents

Advertisement

1.2 Rated input

Input type
K
J
R
S
B
E
T
N
PL-
C(W/Re5-26)
Pt100
JPt100
4 to 20mA DC
0 to 20mA DC
0 to 1V DC
0 to 10V DC
1 to 5V DC
0 to 5V DC
*1: For DC input, the input range and decimal point place can be changed.
*2: For DC current input, 50
connected between input terminals.

1.3 How to read the rated label

The rated label is attached to the case.
(1)
A K T 9 1 1 1 1 0 0 1
(2)
No.
(1) Model number, supply voltage, input type, output type, etc. are entered.
(2) Lot number is entered.
Input range
–200 to 1370
–199.9 to 400.0
–200 to 1000
0 to 1760
0 to 1760
0 to 1820
–200 to 800
–199.9 to 400.0
–200 to 1300
0 to 1390
0 to 2315
–199.9 to 850.0
–200 to 850
–199.9 to 500.0
–200 to 500
–1999 to 9999 *1, *2
–1999 to 9999 *1, *2
–1999 to 9999 *1
–1999 to 9999 *1
–1999 to 9999 *1
–1999 to 9999 *1
shunt resistor (AKT4810, sold separately) must be
(e.g.)
Supply voltage: 100 to 240V AC
Multi-input
Relay contact output

A1 output

Heating/Cooling control is not added.
Heater burnout alarm is not added.
Serial communication is added.
7
–320 to 2500
–199.9 to 750.0
–320 to 1800
0 to 3200
0 to 3200
0 to 3300
–320 to 1500
–199.9 to 750.0
–320 to 2300
0 to 2500
0 to 4200
–199.9 to 999.9
–300 to 1500
–199.9 to 900.0
–300 to 900
Resolution
1 ( )
0.1 ( )
1 ( )
1 ( )
1 ( )
1 ( )
1 ( )
0.1 ( )
1 ( )
1 ( )
1 ( )
0.1 ( )
1 ( )
0.1 ( )
1 ( )
1
1
1
1
1
1

Hide quick links: