Mitsubishi Electric FX3G User Manual page 354

Hide thumbs Also See for FX3G:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
FX
-3A-ADP (2-channel Analog Input, 1-channel Analog Output)
3U
• FX
/FX
3G
3GC
Special
device
Special
auxiliary
relay
Special
data
register
• FX
/FX
3U
3UC
Special
device
1st
M8260 M8270 M8280 M8290 Switches the input mode of channel 1
M8261 M8271 M8281 M8291 Switches the input mode of channel 2
M8262 M8272 M8282 M8292 Switches the output mode.
M8263 M8273 M8283 M8293
Special
M8264 M8274 M8284 M8294
auxiliary
M8265 M8275 M8285 M8295
relay
M8266 M8276 M8286 M8296 Sets the cancel of output holding function.
M8267 M8277 M8287 M8297 Sets whether or not input channel 1 is used.
M8268 M8278 M8288 M8298 Sets whether or not input channel 2 is used.
M8269 M8279 M8289 M8299 Sets whether or not output channel is used.
D8260 D8270 D8280 D8290 Channel-1 input data
D8261 D8271 D8281 D8291 Channel-2 input data
D8262 D8272 D8282 D8292 Output setting data
D8263 D8273 D8283 D8293 Unused (Do not use.)
D8264 D8274 D8284 D8294
Special
data
register
D8265 D8275 D8285 D8295
D8266 D8276 D8286 D8296
D8267 D8277 D8287 D8297
D8268 D8278 D8288 D8298 Error status
D8269 D8279 D8289 D8299 Model code = 50
H-20
PLC User's Manual - Analog Control Edition
3UC
Series PLC
Device number
1st
2nd
M8280
M8290
M8281
M8291
M8282
M8292
M8283 to
M8293 to
M8285
M8296
M8286
M8296
M8287
M8297
M8288
M8298
M8289
M8299
D8280
D8290
D8281
D8291
D8282
D8292
D8283
D8293
D8284
D8294
D8285
D8295
D8286
D8296
D8287
D8297
D8288
D8298
D8289
D8299
Series PLC
Device number
2nd
3rd
4th
Description
Switches the input mode of channel 1
Switches the input mode of channel 2
Switches the output mode.
Unused (Do not use.)
Sets the cancel of output holding function.
Sets whether or not the input channel 1 is
used.
Sets whether or not the input channel 2 is
used.
Sets whether or not the output channel is
used.
Channel-1 input data
Channel-2 input data
Output setting data
Unused (Do not use.)
Averaging time for channel-1
(Setting range: 1 to 4095)
Averaging time for channel-2
(Setting range: 1 to 4095)
Unused (Do not use.)
Error status
Model code = 50
Description
Unused (Do not use.)
Averaging time for channel-1
(Setting range: 1 to 4095)
Averaging time for channel-2
(Setting range: 1 to 4095)
Unused (Do not use.)
4 Programming
4.2 List of Special Devices
R: Read / W: Write
Attribute Reference
R/W
Section 4.3
R/W
R/W
Section 4.4
-
-
R/W
Section 4.5
R/W
R/W
Section 4.6
R/W
R
Section 4.7
R
R/W
Section 4.8
-
-
R/W
Section 4.9
R/W
-
-
R/W
Section 4.10
R
Section 4.11
R: Read / W: Write
Attribute Reference
R/W
Section 4.3
R/W
R/W
Section 4.4
-
-
R/W
Section 4.5
R/W
R/W
Section 4.6
R/W
R
Section 4.7
R
R/W
Section 4.8
-
-
R/W
Section 4.9
R/W
-
-
R/W
Section 4.10
R
Section 4.11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3sFx3gcFx3uFx3uc

Table of Contents