Sound Power Level; Sound Pressure Level; Hand-Arm Vibration Level; Whole Body Vibration Level - Toro 04540 Operator's Manual

Traction unit
Hide thumbs Also See for 04540:
Table of Contents

Advertisement

Use paper or cardboard, not your hands, to search for
leaks. Hydraulic fluid escaping under pressure can have
sufficient force to penetrate the skin and cause serious
injury.
Before disconnecting or performing any work on the
hydraulic system, all pressure in the system must be
relieved by stopping the engine and lowering the cutting
units and attachments to the ground.
Check all fuel lines for tightness and wear on a regular
basis. Tighten or repair them as needed.
If the engine must be running to perform a maintenance
adjustment, keep hands, feet, clothing, and any parts of
the body away from the cutting units, attachments, and
any moving parts, especially the screen at the side of the
engine. Keep everyone away.
Do not overspeed the engine by changing governor
settings. To ensure safety and accuracy, have an
Authorized Toro Distributor check the maximum engine
speed with a tachometer..
The engine must be shut off before checking the oil or
adding oil to the crankcase.
If major repairs are ever needed or if assistance is desired,
contact an Authorized Toro Distributor.
To ensure optimum performance and continued safety
certification of the machine, use only genuine Toro
replacement parts and accessories. Replacement parts
and accessories made by other manufacturers could be
dangerous, and such use could void the product warranty.

Sound Power Level

This unit has a guaranteed sound power level of 97 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in ISO 11094.

Sound Pressure Level

This unit has a sound pressure level at the operator's ear of 81
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound pressure level was determined according to the
procedures outlined in EN ISO 5395:2013.

Hand-Arm Vibration Level

Measured vibration level for right hand = 0.20 m/s
Measured vibration level for left hand = 0.31 m/s
Uncertainty Value (K) = 0.15 m/s
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.
2
2
2

Whole Body Vibration Level

Measured vibration level = 0.14 m/s
Uncertainty Value (K) = 0.07 m/s
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.