Keyboard Unit Test; Relay Test - Sharp KB-3425LS Service Manual

Free standing/slide-in range with microwave drawer
Hide thumbs Also See for KB-3425LS:
Table of Contents

Advertisement

PROCEDURE
LETTER
4) Reconnect all leads removed from components during testing.
5) Re-install the covers.
6) Reconnect the power supply cord after the outer case is installed.
7) Run the oven and check all functions.
B

KEYBOARD UNIT TEST

. Disconnect the power supply cord, and then disassemble as per "OVEN/MICROWAVE DRAWER
DISASSEMBLY" page 40.
2. Open the drawer and block it open.
3. Discharge high voltage capacitor.
4. If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the wire harness
and connectors are making good contact between the control unit and the keyboard, verify that the
door sensing switch operates properly; that is the contacts are closed when the door is closed and
open when the door is open.
5. Remove the old keyboard unit and install the new keyboed unit (as the normal keyboard unit).
6. Reconnect the wire harness to the keyboard unit.
7. If the control unit responds by clearing with a beep when the stop/clear pad is touched, the old
keyboard unit is faulty and must be replaced. If the control unit does not respond, it is faulty and
must be replaced. If a specific pad does not respond, the above method may be used (after clearing
the control unit) to determine if the control unit or keyboed unit is at fault.
8. Reconnect all leads removed from components during testing.
9. Re-install the covers.
0. Reconnect the power supply cord after the outer case is installed.
. Run the oven and check all functions.
C

RELAY TEST

. Disconnect the power supply cord, and then disassemble as per "OVEN/MICROWAVE DRAWER
DISASSEMBLY" page 40.
2. Open the drawer and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that these leads remain isolated from other components and oven chassis by using insulation
tape.
6. After that procedure, re-connect the power supply cord.
7. Remove the covers and check voltage between Pin Nos.  and 3 of the 2 pin connector (CN-B) on
the power unit with an A.C. voltmeter.
The meter should indicate 6 or 20 volts, if not check oven circuit.
RY and RY2 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated - Defective relay.
DC. voltage not indicated - Check diode which is connected to the relay coil. If diode is good,
RELAY SYMBOL
TEST PROCEDURES
control unit is defective.
OPERATIONAL VOLTAGE
RY
Approx. 8V D.C.
RY2
Approx. 8V D.C.
RY3
Approx. 8V D.C.
RY4
Approx. 8V D.C.
RY5
Approx. 24V D.C.
RY6
Approx. 24V D.C.
RY7
Approx. 24V D.C.
RY8
Approx. 24V D.C.
RY9
Approx. 24V D.C.
RY0
Approx. 24V D.C.
RY
Approx. 24V D.C.
RY-B
Approx. 24V D.C.
RY-C
Approx. 24V D.C.
COMPONENT TEST
CONNECTED COMPONENTS
Oven lamp / Stirrer motor
Power transformer
Oven common relay
Top heater
Fan motor (Microwave)
Fan motor (Oven)
Oven lamp (Oven)
Door lock motor (Oven)
Convection motor
Warmer (Cook top)
Switching power supply
Bottom heater
Convection heater
9
KB-3425LS/K/W
KB-4425LS/K/W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kb-4425lsKb-4425lkKb-3425lwKb-4425lwKb-3425lk