Connecting High Ac/Dc Power - Siemens RUGGEDCOM RX1500 Installation Manual

Hide thumbs Also See for RUGGEDCOM RX1500:
Table of Contents

Advertisement

RUGGEDCOM RX1500
Installation Guide
1
2
3
Figure 7: Removing a Power Supply
1. Chassis
2. Power Supply
3.
Install the blank power module assembly into the empy slot to prevent the ingress of dust and dirt.
Section 2.2.2

Connecting High AC/DC Power

To connect a high AC/DC power supply to the device, do the following:
DANGER!
Electrocution hazard – risk of death, serious personal injury and/or damage to the device. Make sure
the supplied cover is always installed over high voltage screw-type terminal blocks.
CAUTION!
Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a 12, 24 or 48
VDC power supply terminal block. Damage to the power supply may occur.
NOTE
The screw-type terminal block is installed using Phillips screws and compression plates, allowing either
bare wire connections or crimped terminal lugs. Use #6 size ring lugs for secure, reliable connections.
1.
Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block.
Connecting High AC/DC Power
3. Screws
Chapter 2
Installing the Device
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ruggedcom rx1512

Table of Contents