Advertisement

Quick Links

RUGGEDCOM RX1511
Installation Guide
09/2017
RC1056-EN-07
Preface
Introduction
Installing the Device
Modules
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RX1511 3

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RX1511 Modules Technical Specifications Dimension Drawings Installation Guide Certification 09/2017 RC1056-EN-07...
  • Page 2 Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM RX1511 Installation Guide Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 www.siemens.com/ruggedcom Concord, Ontario Canada, L4K 5C7...
  • Page 4 RUGGEDCOM RX1511 Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM RX1511   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 Chapter 2 Installing the Device ..................
  • Page 6   RUGGEDCOM RX1511 Table of Contents Installation Guide Chapter 4 Technical Specifications .................. 4.1  Power Supply Specifications ......................31 4.2  Failsafe Relay Specifications ......................32 4.3  Operating Environment ....................... 32 4.4  Mechanical Specifications ......................32 Chapter 5 Dimension Drawings ..................Chapter 6 Certification ....................6.1 ...
  • Page 7: Preface

    RUGGEDCOM RX1511   Installation Guide Preface Preface This guide describes the RUGGEDCOM RUGGEDCOM RX1511. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 9: Customer Support

    RUGGEDCOM RX1511   Installation Guide Preface • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Customer Support...
  • Page 10   RUGGEDCOM RX1511 Preface Installation Guide Customer Support...
  • Page 11: Introduction

    RUGGEDCOM RX1511 Chapter 1 Installation Guide Introduction Introduction The RUGGEDCOM RUGGEDCOM RX1511 is a cost-efficient, rugged Layer 3 switch and router. The RUGGEDCOM RX1511’s modular and field replaceable platform can be equipped with WAN, serial, and Ethernet options, making it ideally suited for electric power utilities, the industrial plant floor, and traffic control systems. The appliance’s compact form factor makes it ideal for pole mount applications or installation in restricted spaces.
  • Page 12: Description

    Chapter 1 RUGGEDCOM RX1511 Introduction Installation Guide Section 1.2 Description The RUGGEDCOM RX1511 features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Figure 1: RUGGEDCOM RX1511 1. Utility USB Port    2. RS232 Serial Console Port (RJ45)    3. Lamp Test/Alarm Cut-Off (LT/ACO) Button    4. Compact Flash Card Port    5. Alarm Indicator LED   ...
  • Page 13 CAUTION! Configuration hazard – risk of data corruption/loss. Do not open the compact flash card port, unless specifically instructed to by a Siemens Customer Support representative. The warranty will be void otherwise. Removing the compact flash card improperly can corrupt configuration data.
  • Page 14 Chapter 1 RUGGEDCOM RX1511 Introduction Installation Guide Description...
  • Page 15: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 16: General Procedure

    Chapter 2 RUGGEDCOM RX1511 Installing the Device Installation Guide • Section 2.4, “Mounting the Device” • Section 2.5, “Connecting the Failsafe Alarm Relay” • Section 2.6, “Connecting Power” • Section 2.7, “Connecting to the Device” • Section 2.8, “Configuring the Device” Section 2.1 General Procedure The general procedure for installing the device is as follows: Review the relevant certification information for any regulatory requirements.
  • Page 17: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 18: Mounting The Device

    Chapter 2 RUGGEDCOM RX1511 Installing the Device Installation Guide Section 2.4 Mounting the Device The RUGGEDCOM RX1511 is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 35 mm (1.4 in) DIN rail, or directly on a panel. IMPORTANT! Heat generated by the device is channeled outwards to the enclosure.
  • Page 19: Mounting The Device To A Panel

    RUGGEDCOM RX1511 Chapter 2 Installation Guide Installing the Device Section 2.4.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RX1511 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws. To mount the device to a panel, do the following: Place the device against the panel and mark the mounting holes on the panel.
  • Page 20: Connecting Power

    Chapter 2 RUGGEDCOM RX1511 Installing the Device Installation Guide The following shows the proper relay connections. Figure 4: Failsafe Alarm Relay Wiring 1. Normally Open    2. Common    3. Normally Closed Section 2.6 Connecting Power The RUGGEDCOM RX1511 supports a single high AC, high DC or low DC power module. Power modules can be equipped with either a screw-type or pluggable terminal block.
  • Page 21: Connecting High Ac/Dc Power

    RUGGEDCOM RX1511 Chapter 2 Installation Guide Installing the Device Section 2.6.1 Connecting High AC/DC Power To connect a high AC/DC power supply to the device, do the following: DANGER! Electrocution hazard – risk of death, serious personal injury and/or damage to the device. Make sure the supplied cover is always installed over high voltage screw-type terminal blocks.
  • Page 22 Chapter 2 RUGGEDCOM RX1511 Installing the Device Installation Guide Figure 6: AC Terminal Block Wiring – Screw-Type Terminal Block for HI Power Supplies 1. 5-Position Terminal Block    2. 3-Position Terminal Block    3. Positive/Live (+/L) Terminal    4. Ground Terminal    5. Negative/Neutral (-/N) Terminal Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block. Connect the negative wire from the power source to the neutral/negative (-/N) terminal on the terminal block.
  • Page 23: Connecting Low Dc Power

    RUGGEDCOM RX1511 Chapter 2 Installation Guide Installing the Device Section 2.6.2 Connecting Low DC Power To connect a low DC power supply to the device, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block.
  • Page 24 Chapter 2 RUGGEDCOM RX1511 Installing the Device Installation Guide Figure 9: DC Terminal Block Wiring – Screw-Type Terminal Block for 12, 24 and 48 Power Supplies 1. 5-Position Terminal Block    2. 3-Position Terminal Block    3. Positive (+) Terminal    4. Negative (-) Terminal    5. Ground Terminal Connect the positive wire from the power source to the positive (+) terminal on the terminal block. Connect the negative wire from the power source to the negative (-) terminal on the terminal block.
  • Page 25: Connecting To The Device

    RUGGEDCOM RX1511 Chapter 2 Installation Guide Installing the Device Section 2.7 Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM ROX II console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROX II User Guide for the RUGGEDCOM RX1511.
  • Page 26: Configuring The Device

    Chapter 2 RUGGEDCOM RX1511 Installing the Device Installation Guide Name Description Receive Data+ Receive Data- Transmit Data+ Reserved (Do Not Connect) Figure 12: RJ-45 Management Port Reserved (Do Not Connect) Transmit Data- Reserved (Do Not Connect) Reserved (Do Not Connect) Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM ROX II console and Web interfaces via the device's IP address.
  • Page 27: Modules

    RUGGEDCOM RX1511 Chapter 3 Installation Guide Modules Modules The RUGGEDCOM RX1511 features slots for up to two field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit specific applications. A variety of modules are available, each featuring a specific type of communication port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular modem and DDS.
  • Page 28: Available Modules

    The following is a list of all power and line modules available for use in the RUGGEDCOM RX1511. For more RUGGEDCOM RX1500 Series Modules Catalog information about individual modules, refer to the [https:// support.industry.siemens.com/cs/ca/en/view/109747072]. Power Supply Modules RUGGEDCOM RX1500PN PS 12 Specifications...
  • Page 29 RUGGEDCOM RX1511 Chapter 3 Installation Guide Modules RUGGEDCOM RX1500PN PS 48 Specifications Article Numbers Input Range: 36 to 72 VDC 6GK6015-0AL12-0AA0 (Standard) Terminal Type: Screw 6GK6015-0AL12-0AA1 (Conformal Coated) RUGGEDCOM RX1500PN PS 48P Specifications Article Numbers Input Range: 36 to 72 VDC 6GK6015-0AL15-0AA0 (Standard) Terminal Type: Pluggable...
  • Page 30 Chapter 3 RUGGEDCOM RX1511 Modules Installation Guide RUGGEDCOM RX1500PN LM CG03B Specifications Article Numbers Ports: 2 6GK6015-0AL20-0PE0 (Standard) Speed: 1000 Mbps 6GK6015-0AL20-0PE1 (Conformal Coated) Interface: TX Port Type: M12 (8-Pin, A-Coded, Controlled Bypass) Distance: 100 m (328 ft) RUGGEDCOM RX1500PN LM X CG04 Specifications Article Numbers Ports: 2...
  • Page 31 RUGGEDCOM RX1511 Chapter 3 Installation Guide Modules RUGGEDCOM RX1500PN LM 6TX01 Specifications Article Numbers Ports: 6 6GK6015-0AL20-0NB0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0NB1 Interface: TX (Conformal Coated) Port Type: RJ45 Distance: 100 m (328 ft) Fiber Optic Ethernet Modules RUGGEDCOM RX1500PN LM 4FX11 Specifications Article Numbers Mode: MM...
  • Page 32 Chapter 3 RUGGEDCOM RX1511 Modules Installation Guide RUGGEDCOM RX1500PN LM 6FX50 Specifications Article Numbers SFP Sockets: 6 6GK6015-0AL20-0JD0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0JD1 (Conformal Coated) WAN Modules RUGGEDCOM RX1500PN LM S01 Specifications Article Numbers (Standard) Standard: RS232/RS422/RS485 6GK6015-0AL20-0KB0 (Standard) Ports: 6 6GK6015-0AL20-0KB1 Port Type: RJ45 (Conformal Coated)
  • Page 33 RUGGEDCOM RX1511 Chapter 3 Installation Guide Modules SIM: Dual Mini-SIM (2FF) RUGGEDCOM RX1500PN LM W12 Specifications Article Numbers (Standard) Services: GSM/EDGE/HSPA+ 6GK6015-0AL20-0WC0 (Standard) Region: North America (AT&T), European Union, Australia 6GK6015-0AL20-0WC1 (Conformal Coated) Port Type: 50 Ω SMA Antennas: 2 x GSM/EDGE/HSPA+, 2 x Receive Diversity (Secondary) SIM: Dual Mini-SIM (2FF) RUGGEDCOM RX1500PN LM W21...
  • Page 34 Chapter 3 RUGGEDCOM RX1511 Modules Installation Guide SIM: Dual Mini-SIM (2FF) RUGGEDCOM RX1500PN LM W61 Specifications Article Numbers (Standard) Services: 4G LTE/HSPA+/CDMA/ 6GK6015-0AL20-0WJ0 EVDO/GPS/GNSS (Standard) Region: North America (Verizon, 6GK6015-0AL20-0WJ1 Sprint) (Conformal Coated) Port Type: 50 Ω SMA Antennas: 1 x LTE Main, 1 x LTE MIMO, 1 x GPS SIM: Dual Mini-SIM (2FF) RUGGEDCOM RX1500PN LM W81...
  • Page 35 RUGGEDCOM RX1511 Chapter 3 Installation Guide Modules RUGGEDCOM RX1500PN LM APE1404 Specifications Article Numbers (Standard) Operating System: Debian Linux® 6GK6015-0AL20-0GD0 (Standard) Processor: Intel Atom E660T 1.3 GHz, 512 KB L2 Cache 6GK6015-0AL20-0GD1 (Conformal Coated) RAM: 2 GB DDR2, 800 MHz, 32- Disk: 16 GB SATA, Solid State Networking: Realtek RTL8111, RJ45 Gigabit Ethernet Interface...
  • Page 36: Installing/Removing Line Modules

    Chapter 3 RUGGEDCOM RX1511 Modules Installation Guide RUGGEDCOM RX1500PN LM Blank Specifications Article Numbers — 6GK6015-0AL20-0AA0 (Standard) 6GK6015-0AL20-0AA1 (Conformal Coated) Section 3.2 Installing/Removing Line Modules Upon installing a new line module in the device, all features associated with the module are available in RUGGEDCOM ROX II.
  • Page 37 RUGGEDCOM RX1511 Chapter 3 Installation Guide Modules Figure 14: Removing a Module 1. Module    2. Chassis    3. Screw Install a new module or a blank module (to prevent the ingress of dust and dirt). [Optional] If necessary, install the device in the rack. Connect power to the device. Installing a Module To install a line module, do the following: Make sure power to the device has been disconnected and wait approximately two minutes for any remaining...
  • Page 38: Installing/Removing Power Modules

    Chapter 3 RUGGEDCOM RX1511 Modules Installation Guide Figure 15: Installing a Module 1. Module    2. Chassis    3. Screw Tighten the screws to secure the module. [Optional] If necessary, install the device in the rack. Connect power to the device. Section 3.3 Installing/Removing Power Modules The RUGGEDCOM RX1511 supports a single power module. Figure 16: ...
  • Page 39 RUGGEDCOM RX1511 Chapter 3 Installation Guide Modules CAUTION! Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris that may lead to premature equipment failure. Always make sure slots are not left empty. Removing a Power Module To remove a power module, do the following: Loosen the screws that secure the module to the chassis until the module can be removed.
  • Page 40 Chapter 3 RUGGEDCOM RX1511 Modules Installation Guide Insert the module into the empty slot. Figure 18: Installing a Power Module 1. Chassis    2. Power Module    3. Screws Hand-tighten the screws to secure the power module to the chassis. Turn on power to the module and confirm the module is receiving and supplying power. This is indicated by the LEDs on the module.
  • Page 41: Technical Specifications

    RUGGEDCOM RX1511 Chapter 4 Installation Guide Technical Specifications Technical Specifications This section provides important technical specifications related to the device. CONTENTS • Section 4.1, “Power Supply Specifications” • Section 4.2, “Failsafe Relay Specifications” • Section 4.3, “Operating Environment” • Section 4.4, “Mechanical Specifications” Section 4.1 Power Supply Specifications Input Range Power...
  • Page 42: Failsafe Relay Specifications

    Chapter 4 RUGGEDCOM RX1511 Technical Specifications Installation Guide Section 4.2 Failsafe Relay Specifications Maximum Switching Voltage Rated Switching Current Isolation 30 VDC 2800 VDC for 1 minute 250 VAC 6.25 A Section 4.3 Operating Environment The RUGGEDCOM RX1511 is rated to operate under the following environmental conditions. IMPORTANT! Temperature limits for select line modules may differ from that which can be withstood by the RUGGEDCOM RX1511.
  • Page 43: Dimension Drawings

    RUGGEDCOM RX1511 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 199.6 122.7 Figure 19: Overall Dimensions...
  • Page 44 Chapter 5 RUGGEDCOM RX1511 Dimension Drawings Installation Guide 199.9 152.4 189.8 78.2 Figure 20: Panel and Din Rail Mount Dimensions 162.5 151.4 19.7 Figure 21: Line Module Dimensions...
  • Page 45 RUGGEDCOM RX1511 Chapter 5 Installation Guide Dimension Drawings 162.5 151.8 40.6 Figure 22: Power Module Dimensions...
  • Page 46 Chapter 5 RUGGEDCOM RX1511 Dimension Drawings Installation Guide...
  • Page 47: Certification

    RUGGEDCOM RX1511 Chapter 6 Installation Guide Certification Certification The RUGGEDCOM RX1511 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. NOTE Certifications related to individual modules are detailed in the RUGGEDCOM Modules Catalog for the device available online.
  • Page 48: European Union (Eu)

    The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens”.
  • Page 49: Fcc

    • Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health Section 6.1.5 ISED This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) Section 6.1.6...
  • Page 50: Other Approvals

    Chapter 6 RUGGEDCOM RX1511 Certification Installation Guide Section 6.1.7 Other Approvals This device meets the requirements of the following additional standards: • IEEE 1613 IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations • IEC 61000-6-2 Electromagnetic Compatibility (EMC) –...
  • Page 51 5 kV (Failsafe Relay output) DC Power Ports 5 kV AC Power Ports Siemens-specified severity levels EMC Immunity Type Tests for IEEE 1613 NOTE The RUGGEDCOM RX1511 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 52 Chapter 6 RUGGEDCOM RX1511 Certification Installation Guide Description Test Levels Earth ground ports Oscillatory Signal ports 2.5 kV common mode @1MHz DC Power Ports 2.5 kV common 1 kV differential mode @ 1 MHz AC Power Ports Radiated RFI Enclosure ports 35 V/m Enclosure Contact ±...

Table of Contents