GE N60 UR Series Instruction Manual page 412

Network stability and synchrophasor measurement system
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 47 of 54)
ADDR
REGISTER NAME
CAE1
Direct I/O Ch 1 Unreturned Messages Alarm Msg Count
CAE2
Direct I/O Ch 1 Unreturned Messages Alarm Threshold
CAE3
Direct I/O Ch 1 Unreturned Messages Alarm Events
CAE4
Reserved (4 items)
CAE8
Direct IO Ch 2 Unreturned Messages Alarm Function
B
CAE9
Direct I/O Ch 2 Unreturned Messages Alarm Msg Count
CAEA
Direct I/O Ch 2 Unreturned Messages Alarm Threshold
CAEB
Direct I/O Channel 2 Unreturned Messages Alarm Events
CAEC
Reserved (4 items)
Remote Devices (Read/Write Setting) (16 modules)
CB00
Remote Device 1 GSSE/GOOSE Application ID
CB21
Remote Device 1 GOOSE Ethernet APPID
CB22
Remote Device 1 GOOSE Dataset
CB23
...Repeated for Device 2
CB46
...Repeated for Device 3
CB69
...Repeated for Device 4
CB8C
...Repeated for Device 5
CBAF
...Repeated for Device 6
CBD2
...Repeated for Device 7
CBF5
...Repeated for Device 8
CC18
...Repeated for Device 9
CC3B
...Repeated for Device 10
CC5E
...Repeated for Device 11
CC81
...Repeated for Device 12
CCA4
...Repeated for Device 13
CCC7
...Repeated for Device 14
CCEA
...Repeated for Device 15
CD0D
...Repeated for Device 16
CD30
...Repeated for Device 17
CD53
...Repeated for Device 18
CD76
...Repeated for Device 19
CD99
...Repeated for Device 20
CDBC
...Repeated for Device 21
CDDF
...Repeated for Device 22
CE02
...Repeated for Device 23
CE25
...Repeated for Device 24
CE48
...Repeated for Device 25
CE6B
...Repeated for Device 26
CE8E
...Repeated for Device 27
CEB1
...Repeated for Device 28
CED4
...Repeated for Device 29
CEF7
...Repeated for Device 30
CF1A
...Repeated for Device 31
CD3D
...Repeated for Device 32
Remote Inputs (Read/Write Setting) (64 modules)
CFA0
Remote Input 1 Device
CFA1
Remote Input 1 Item
CFA2
Remote Input 1 Default State
CFA3
Remote Input 1 Events
CFA4
Remote Input 1 Name
CFAA
...Repeated for Remote Input 2
CFB4
...Repeated for Remote Input 3
CFBE
...Repeated for Remote Input 4
CFC8
...Repeated for Remote Input 5
B-54
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
STEP
100 to 10000
---
1 to 1000
---
0 to 1
---
1 to 1000
---
0 to 1
---
100 to 10000
---
1 to 1000
---
0 to 1
---
---
---
---
---
---
0 to 16383
---
0 to 8
---
1 to 16
---
0 to 64
---
0 to 3
---
0 to 1
---
1 to 64
---
APPENDIX B
FORMAT
DEFAULT
1
F001
600
1
F001
10
1
F102
0 (Disabled)
1
F001
10
1
F102
0 (Disabled)
1
F001
600
1
F001
10
1
F102
0 (Disabled)
1
F001
10
F209
"Remote Device 1"
1
F001
0
1
F184
0 (Fixed)
1
F001
1
1
F156
0 (None)
1
F086
0 (Off)
1
F102
0 (Disabled)
1
F205
"Rem Ip 1"
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents