Allowable Load of Output Shaft

Dimensional Outline Drawing
Motor
Series
MUMA
<Remarks>
If a position of load point varies, calculate allowable radial load P (N) from distance L (mm) of a load point
from mounting flange face, based on the relational expression, so that the result of calculation will be as
follows:
Radial Load Direction (P)
LR
LR/2
P
When Assembled
Motor Output
Radial Load
50W, 100W
147
200W, 400W
392
L
P
Thrust Load Directions (A, B)
A
M
B
Unit: N (1kgf = 9.8N)
Thrust Load
Radial Load
Direction A
Direction B
88.2
117.6
68.6
147
196
245
Motor
Relational Expression
Motor Output
Series
of Load - Load Point
50W, 100W
MUMA
200W
400W
196
In Operation
Thrust Load
Directions A, B
58.8
98
1406
P =
L + 7.5
2940
P =
L – 3
5831
P =
L + 8.8