Service Mode; Power Supply; Power Supply Features; Power Consumption - Philips BDL4230E/00 Service Manual

42 inch fhd lcd public display
Hide thumbs Also See for BDL4230E/00:
Table of Contents

Advertisement

70 BDL4230E LCD

2.4 Service mode

Detailed technical specification refers to Service delta technical specs.
Software Update:
Wireless data cloning (IR transmission).
Through RS-232

2.5 Power Supply

2.5.1 Power supply features

AC line voltage range -
AC line frequency range -
DC tact switch -
AC mains switch -
Inrush current -
Leakage current -
Power factor correction -

2.5.2 Power consumption

Normal on -
Standby -
Switch off (DC or TACT) - < 1w, RC in-active
Switch off (AC mains) -
2.5.3 Display DPM standby (D-sub & HDMI input)
DPM -
Recovery from DPM -
Standby - The Display enters "AV standby mode" when it's switched off by RC.
Recovery from Standby - Power & function recovers when RC "Standby" or "CH +/-" or

2.6 User Control Interface

Controlled via top control keypads or remote control or RS-232.

2.6.1 Hidden controls

It can't be easily accessed in front of the set.
TBC
General Product Specification
90Vac ~ 264Vac.
Minimal power consumption when switch off
< 40A at 240Vac when cold start.
TBD w (typical), TBD w(max.)
The Display enters DPM off (sleep) mode when no H&V sync, one of H-sync /
V-sync input or digital clock is absent. "No Video Input" message appears before
entering DPM mode. A delay of 30 seconds before entering the power saving
state is required to avoid misunderstanding of display resolution and timing mode
changes.
Power & function recover when either H & V syncs or digital
clock are detected.
"Standby/Power" key or SLEEP TIMER function is activated or no AV signal
input for 30 minutes.
"AV" is pressed. Hidden key control "Menu" or "CH +/-" key is
toggled.
50-60 Hz
3 Hz.
No power consumption when switch off.
< 0.5mA at 240Vac.
According to EN61000-3-2
< 1w, RC standby mode
< No power consumption.