Import Firmware Certificate; Import Firmware Certificate Monitoring - GE MDS ORBIT MCR Technical Manual

Multiservice/edge connect routers
Table of Contents

Advertisement

The MCR supports file uploads through a web browser from a local file on the user's PC. The MCR also
supports HTTP, FTP, TFTP, and SFTP file downloads using external remote servers.
File Source - File transfer method to use. Available choices are From Local File (DEFAULT),
From HTTP Server, From FTP Server, From TFTP Server, and From SFTP Server. Local file
uploads are only available through the web UI and not through the CLI
Certificate Identity - The ID to ssign to the certificate once it is imported
Local File - For a local file, the file to upload as chosen by the file dialog popped up by the
Select File... button
URL - For HTTP, the location of the source file
Server Address - For FTP, TFTP, and SFTP, the remote server's host name or IP address
File Path - For FTP, TFTP, and SFTP, the path to the source file on the remote server
User Name - For FTP and SFTP, the user name on the remote server
Password - For FTP and SFTP, the password on the remote server
Control Port - For FTP, the TCP control port (advanced setting - use default)
Data Port - For FTP, the TCP data port (advanced setting - use default)
Block Size - For TFTP, the block size as defined in RFP 2348 (advanced setting - use default)
Timeout - For FTP, TFTP, and SFTP, the timeout in seconds (advanced setting - use default)
The following example shows how to have the device download a firmware certificate file (named
firmware_cert_2048.pem) from a TFTP server running on a host (address 192.168.1.10) that is accessible
from the MCR (e.g. a locally connected host or remote host accessible via cellular interface). To start the
firmware certificate import from the CLI, enter the following command to download the firmware
certificate file from the TFTP server:
> request pki firmware-certs import cert-identity firmware_cert_2048 filename
firmware_cert_2048.pem manual-file-server { tftp { address 192.168.1.10 } }
Monitoring - Import
Once the import of a firmware certificate is begun, the process may be cancelled by clicking the Cancel
Import button. The current status of the import process is displayed on the web page. Note that the web
page does not display the current status if the device has not been instructed to import a firmware
certificate (in other words, if the state is "inactive").
The import status contains the following items:
MDS 05-6632A01, Rev. F
Figure 3-242. Import Firmware Certificate
Figure 3-243. Import Firmware Certificate Monitoring
MDS Orbit MCR/ECR Technical Manual
377