Interface Configuration; Serial Interface; Com1 Configuration Screen - GE MDS ORBIT MCR Technical Manual

Multiservice/edge connect routers
Table of Contents

Advertisement

The following sections describe key operational features of the MCR unit and list configuration options
for them. Each major heading begins at the top of a new page. For this reason, large areas of white space
exist at the end of some sections. This is done to provide a clear delineation between major sections.
NOTE
The LAN port should be assigned IP addresses only if it is a routed interface (that is, not in a
bridge).
NOTE
The commands that follow in this section vary depending on the Orbit MCR options ordered.

3.5 Interface Configuration

3.5.1

Serial Interface

A serial cable (RJ45 cable with proper ETH to DB9 converter) may be used to connect to a COM port on
the unit to access the CLI. The default serial console settings are 115200 bps with 8N1 format. A mini-
USB-to-USB cable may also be used to connect to a Computer in case no serial port exists. If a mini-USB
connection is used, the computer must contain the appropriate device driver. A driver for serial operation
can be found on GE MDS website.
Configuring
The screens below shows console access to the COM1 serial and USB port:
Navigate to: Serial ---> Basic Config / Ports
Click on COM1 to get:
MDS 05-6632A01, Rev. F
Figure 3-21. COM1 Configuration Screen
MDS Orbit MCR/ECR Technical Manual
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds orbit ecr

Table of Contents