6.3 Ethernet Connection

6.3.1
System configuration for connecting to MP-920 or MP2200 or MP2300 or
MP2300S or CP-9200SH or CP-312 or CP-317
MP920,MP2200,
MP2300,
CP-9200SH,CP-312,
CP-317
PLC
Communication
Model name
*4
module
MP-920
218IF
MP2200
218IF-01
MP2300
218IF-02
MP2300S
MP2300S
-
CP-9200SH
CP-218IF
CP-312
CP-317
218TXB
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
*2
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*3
When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
*4
Product manufactured by YASKAWA Electric Corporation. For details of the product, contact YASKAWA Electric Corporation.
*5
GT14 models compatible with Ethernet connection are only GT1455-QTBDE, GT1450-QMBDE and GT1450-QLBDE.
6 - 20
6. CONNECTION TO YASKAWA PLC
6.3 Ethernet Connection
Communications
Module
Connection cable
*1
Cable model
• 10BASE-T
Shielded twisted pair cable (STP) or
unshielded twisted pair cable (UTP) :
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair cable (STP) :
Category 5 and 5e
GT16 User's Manual
Connection cable
Maximum
segment
Option device
*2
length
- (Built into GOT)
100m
GT15-J71E71-100
- (Built into GOT)
100m
GT15-J71E71-100
- (Built into GOT)
100m
GT15-J71E71-100
- (Built into GOT)
100m
GT15-J71E71-100
- (Built into GOT)
100m
GT15-J71E71-100
Communication driver
GOT
Ethernet(
GOT
Number of connectable
*3
Model
*5
When PLC (module):GOT is N:1
*5
The following shows the number
of PLCs for 1 GOT
<For GT16, GT14>
TCP: 128 or less
*5
UDP: 128 or less
<For GT15, GT12>
TCP: 10 or less
UDP: 128 or less
*5
When PLC (module):GOT is 1:N
The following shows the number
of GOTs for 1 PLC (module)
TCP/UDP: 10 or less
*5
), Gateway
YASKAWA
equipment