Siemens SCALANCE X414-3E Compact Operating Instructions
Siemens SCALANCE X414-3E Compact Operating Instructions

Siemens SCALANCE X414-3E Compact Operating Instructions

Industrial ethernet switches

Advertisement

SCALANCE X-400
SIMATIC NET
Industrial Ethernet Switches
SCALANCE X-400
Compact Operating Instructions
10/2013
A5E01020054-06
___________________
Introduction
___________________
Safety instructions
___________________
Description
___________________
Installation
___________________
Connecting up
___________________
Certifications and approvals
___________________
Technical specifications
___________________
Dimension drawings
1
2
3
4
5
6
7
8

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE X414-3E

  • Page 1 ___________________ SCALANCE X-400 Introduction ___________________ Safety instructions ___________________ Description SIMATIC NET ___________________ Installation Industrial Ethernet Switches ___________________ SCALANCE X-400 Connecting up ___________________ Certifications and approvals Compact Operating Instructions ___________________ Technical specifications ___________________ Dimension drawings 10/2013 A5E01020054-06...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    5.1.2 Connectors of the signaling contact and grounding strap (X2) of the SCALANCE X-400 ..31 5.1.3 Connectors of the digital inputs of the SCALANCE X414-3E ............32 Certifications and approvals ........................35 Approvals, Certificates ......................... 35 Technical specifications ........................41 SCALANCE X414-3E and X408-2 - technical specifications ............
  • Page 4 Table of contents SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 5: Introduction

    Introduction Content of the document These operating instructions (compact) contain information with which you will be able to install and connect up a device of the SCALANCE X-400 product line. Names of the devices in these operating instructions (compact) The descriptions in these operating instructions (compact) always apply to the devices of the SCALANCE X-400 product line unless the description relates to a specific device of the product line.
  • Page 6 Introduction SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 7: Safety Instructions

    Safety instructions Important notes on using the device Safety notices on the use of the device The following safety notices must be adhered to when setting up and operating the device and during all work relating to it such as installation, connecting up, replacing devices or opening the device.
  • Page 8 Safety instructions 2.1 Important notes on using the device Information on use in hazardous areas WARNING Risk of explosion when connecting or disconnecting the device EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. WARNING Replacing components EXPLOSION HAZARD...
  • Page 9 Safety instructions 2.1 Important notes on using the device Information on use in hazardous areas according to ATEX WARNING Requirements for the cabinet/enclosure To comply with EU Directive 94/9 (ATEX95), this enclosure must meet the requirements of at least IP54 in compliance with EN 60529. The fiber-optic bus connections labeled SCALANCE MM400 (see type plate) may also be led through a hazardous area zone1 (see also Auto-Hotspot, section "Explosion Protection Directive (ATEX)").
  • Page 10 Safety instructions 2.1 Important notes on using the device SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 11: Description

    SCALANCE X414-3E basic device - overview Overview The SCALANCE X414-3E has two integrated gigabit Ethernet twisted pair ports (10, 100 or 1000 Mbps) to interconnect multiple switches. The nodes are connected over 12 Fast Ethernet ports integrated in the switch (10 or 100 Mbps).
  • Page 12 Basic device with media modules and covers Components of the product The following components are supplied with the SCALANCE X414-3E: ● Basic device with power module in slot 2,
 DI module with eight digital inputs in slot 3
, CPU module including C-PLUG in slot 4
, protective caps for media module terminal strips in slots
...
  • Page 13 Description 3.1 SCALANCE X414-3E basic device - overview Spare parts ● 1 C-PLUG (order number: 6GK1 900-0AB00) ● Cover set CV490 (order number: 6GK5 490-0AA00-0AA2) – 1 cover CV490 2x1000 – 2 covers CV490 2x100 – 1 dummy cover CV490 –...
  • Page 14: Scalance X408-2 Basic Device - Overview

    Description 3.2 SCALANCE X408-2 basic device - overview SCALANCE X408-2 basic device - overview Overview The SCALANCE X408-2 has four integrated gigabit Ethernet twisted-pair interfaces (10, 100 or 1000 Mbps) to interconnect multiple switches and to connect end devices. Further nodes are connected over four Fast Ethernet ports integrated in the switch (10 or 100 Mbps).
  • Page 15 Description 3.2 SCALANCE X408-2 basic device - overview Figure 3-4 SCALANCE X408-2 basic device with media modules and covers Components of the product The following components are supplied with the SCALANCE X408-2: ● Basic device with power module, CPU module including C-PLUG on slots 2 and 3. Covers for media module terminal strips on slots 5 and 6.
  • Page 16 Description 3.2 SCALANCE X408-2 basic device - overview Spare parts ● 1 C-PLUG (order number: 6GK1 900-0AB00) ● Cover set CV490 (order number: 6GK5 490-0AA00-0AA2) – 1 cover CV490 2x1000 – 2 covers CV490 2x100 – 1 dummy cover CV490 –...
  • Page 17: Unpacking And Checking

    Description 3.3 Unpacking and checking Unpacking and checking Unpacking, checking 1. Make sure that the package is complete. 2. Check all the parts for transport damage. WARNING Do not use any parts that show evidence of damage! SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 18 Description 3.3 Unpacking and checking SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 19: Installation

    Installation Safety notices for installation WARNING If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 50 °C.
  • Page 20: Installing / Uninstalling The Scalance X-400

    400. The following figure shows the space you need to allow for an IE Switch X-400. Figure 4-1 Installation clearances for the IE Switches X-400 based on the example of a SCALANCE X414-3E with extender module See also SCALANCE X414-3E and X408-2 - technical specifications (Page 41)
  • Page 21: Installing / Uninstalling With An S7-300 Standard Rail

    Installation 4.2 Installing / uninstalling the SCALANCE X-400 4.2.1 Installing / uninstalling with an S7-300 standard rail Installing on an S7-300 standard rail For installation, you require a slotted screwdriver with a 5.5 mm wide blade. Note When installing the IE Switch X-400, hold it by the backplane and not by the modules, otherwise the device may be damaged.
  • Page 22 Installation 4.2 Installing / uninstalling the SCALANCE X-400 Removing from the S7-300 standard rail To remove the device, you require a slotted screwdriver with a 5.5 mm wide blade. Note When uninstalling the IE Switch X-400, hold it by the backplane and not by the modules, otherwise the device may be damaged.
  • Page 23: Installing / Uninstalling With A 35 Mm Din Rail

    Installation 4.2 Installing / uninstalling the SCALANCE X-400 4.2.2 Installing / uninstalling with a 35 mm DIN rail Installation on a 35 mm DIN rail CAUTION If the IE Switch X-400 is liable to be subjected to severe vibration (> 10 g), use the S7-300 standard rail for installation.
  • Page 24 Note When uninstalling the SCALANCE X414-3E, hold it by the backplane and not by the modules, otherwise the device may be damaged. To remove the device, follow the steps below: 1.
  • Page 25 Installation 4.2 Installing / uninstalling the SCALANCE X-400 Removing the SCALANCE X408-2 from a 35 mm DIN rail Since the two captive screws are not used to secure the device when removing from a 35 mm DIN rail, it is not absolutely necessary to remove the covers and the blind cover, although this does make it easier to handle the basic device.
  • Page 26: Fitting / Removing A Cover And Dummy Cover

    SCALANCE X408-2: 4 and 7 Fitting a cover/dummy cover There is only a dummy cover (no port displays to the front) on slot 8 (SCALANCE X414-3E) or slot 7 (SCALANCE X408-2). To fit a cover, you do not require any tools.
  • Page 27 Installation 4.3 Fitting / removing a cover and dummy cover Removing a cover/dummy cover To remove a cover, you do not require any tools. 1. Press on the fluted middle section of the top of the cover/dummy cover next to the backplane.
  • Page 28 Installation 4.3 Fitting / removing a cover and dummy cover SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 29: Connecting Up

    Connecting up Connectors 5.1.1 Connectors of the power supply (X1) of the SCALANCE X-400 Polarity reversal protection X1, X2 The two 4-pin male connectors (X1, X2) for the power supply and the signaling contact have no polarity reversal protection. If the connectors are accidentally swapped over, this does not cause damage or destroy circuits.
  • Page 30 Connecting up 5.1 Connectors NOTICE If IE Switches X-400 are supplied over long 24 V power supply lines or networks, measures are necessary to prevent interference by strong electromagnetic pulses on the supply lines. These can result, for example, due to lightning or switching of large inductive loads. One of the tests used to attest the immunity of devices of the IE Switches X-400 to electromagnetic interference is the "surge immunity test"...
  • Page 31: Connectors Of The Signaling Contact And Grounding Strap (X2) Of The Scalance X-400

    Connecting up 5.1 Connectors 5.1.2 Connectors of the signaling contact and grounding strap (X2) of the SCALANCE X-400 Polarity reversal protection X1, X2 The two 4-pin male connectors (X1, X2) for the power supply and the signaling contact have no polarity reversal protection. If the connectors are accidentally swapped over, this does not cause damage or destroy circuits.
  • Page 32: Connectors Of The Digital Inputs Of The Scalance X414-3E

    Connecting up 5.1 Connectors 5.1.3 Connectors of the digital inputs of the SCALANCE X414-3E Polarity reversal protection X1, X2 The two 5-pin male connectors (X1, X2) of the digital inputs 1 through 8 have no polarity reversal protection. If the connectors are accidentally swapped over, this does not cause damage or destroy circuits.
  • Page 33 Connecting up 5.1 Connectors Digital inputs 5 to 8 on male connector X2 Digital inputs 5 through 8 are connected using a 5-pin connector at the rear terminal block on the DI module. Figure 5-4 Pins of connector X2 (inputs 5-8) Conn.
  • Page 34 Connecting up 5.1 Connectors SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 35: Certifications And Approvals

    --> Entry type "Certificates" --> Certificate type "Declaration of Conformity" Example German: "EG-Konformitätserklärung SCALANCE X414-3E", Example English: "Declaration of Conformity SCALANCE X414-3E". EMC directive (electromagnetic compatibility) The SIMATIC NET product meets the requirements of the EC Directive: 2004/108/EEC "Electromagnetic Compatibility"...
  • Page 36 Certifications and approvals 6.1 Approvals, Certificates WARNING Personal injury and damage to property may occur. The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility.
  • Page 37 Certifications and approvals 6.1 Approvals, Certificates Note for the manufacturers of machines This product is not a machine in the sense of the EC Machinery Directive. There is therefore no declaration of conformity relating to the EC Machinery Directive 89/392/EEC for this product.
  • Page 38 Certifications and approvals 6.1 Approvals, Certificates Notice for Australia The product meets the requirements of the AS/NZS 2064 standard (Class A). cULus Approval for Information Technology Equipment cULus Listed I. T. E. Underwriters Laboratories Inc. to ● UL 60950-1 (Information Technology Equipment) ●...
  • Page 39 The following media modules meet the FDA and IEC requirements listed below: ● MM491-2LD ● MM491-2LH+ ● MM492-2 ● MM492-2LD ● MM492-2LH ● MM492-2LH+ ● MM492-2ELH Figure 6-1 FDA and IEC approvals See also http://support.automation.siemens.com/WW/view/de/67218486 (http://support.automation.siemens.com/WW/view/en/67218486) SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 40 Certifications and approvals 6.1 Approvals, Certificates SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 41: Technical Specifications

    Technical specifications SCALANCE X414-3E and X408-2 - technical specifications Interfaces SCALANCE X414-3E SCALANCE X408-2 Connecting end devices or 2 x RJ-45 jack (10/100/1000 4 x RJ-45 jack (10/100/1000 network segments over twisted Mbps) Mbps) pair 12 x RJ-45 jack (10/100 Mbps) 
4 x RJ-45 jack (10/100 Mbps)
  • Page 42 Technical specifications 7.1 SCALANCE X414-3E and X408-2 - technical specifications SCALANCE X414-3E SCALANCE X408-2 Current consumption at 24 V DC < 2000 mA < 700 mA Load on the signaling contact 24 V DC / max. 100 mA safety 24 V DC / max. 100 mA safety...
  • Page 43 Technical specifications 7.1 SCALANCE X414-3E and X408-2 - technical specifications Cascading depth SCALANCE X414-3E SCALANCE X408-2 Linear/star structure Any (only depending on signal Any (only depending on signal propagation time) propagation time) Ring with redundancy manager 50 (for reconfiguration time <...
  • Page 44 Technical specifications 7.1 SCALANCE X414-3E and X408-2 - technical specifications Permitted environmental conditions / EMC SCALANCE X414-3E SCALANCE X408-2 Operating temperature Product version for 01 to 06 0°C through + 60°C 0°C to + 60°C Product version as of 07 -40°C to + 70°C...
  • Page 45: Dimension Drawings

    Dimension drawings Dimension drawing - SCALANCE X414-3E Dimension drawing X414-3E Figure 8-1 SCALANCE X414 front SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 46 Dimension drawings 8.1 Dimension drawing - SCALANCE X414-3E Figure 8-2 SCALANCE X414 top Figure 8-3 SCALANCE X414 left SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 47: Dimension Drawing - Scalance X408-2

    Dimension drawings 8.2 Dimension drawing - SCALANCE X408-2 Dimension drawing - SCALANCE X408-2 Dimension drawing X408-2 Figure 8-4 SCALANCE X408 front SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 48 Dimension drawings 8.2 Dimension drawing - SCALANCE X408-2 Figure 8-5 SCALANCE X408 top Figure 8-6 SCALANCE X408 left SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 49 Dimension drawings 8.2 Dimension drawing - SCALANCE X408-2 SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 50 Dimension drawings 8.2 Dimension drawing - SCALANCE X408-2 SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...
  • Page 51: Index

    ATEX, 9 UL-HazLoc, 9 Uninstalling, 25 Basic device, 22 Basic device SCALANCE X408-2, Components of the product SCALANCE X408-2, 15 SCALANCE X414-3E, 12 Connectors Digital Inputs, 32 Power supply, 29 Signaling contact, 31 Connectors Power supply, 29 EMC directive, 35...
  • Page 52 Index SCALANCE X-400 Compact Operating Instructions, 10/2013, A5E01020054-06...

This manual is also suitable for:

Scalance x408-2

Table of Contents