19.2.1 PBX Configuration—[11-2-1] Maintenance—CS Synchronization—Air Synchronization
19.2 PBX Configuration—[11-2] Maintenance—CS
Synchronization
19.2.1 PBX Configuration—[11-2-1] Maintenance—CS
Synchronization—Air Synchronization
You can program and view settings for Air Synchronization Groups.
Select an Air Synchronization Group (1-16) to program from the Air Synchronization Group Number
drop-down list.
It is possible to synchronize CSs with each other within the air synchronization group.
Click Sort to reorder CSs with traditional CSs first, followed by IP-CSs.
To open the screen described in 7.4.4 Utility—Monitor/Trace—CS Status Monitor—Air Sync Group, click
CS Status Monitor.
Air Synchronization Groups can be programmed only in On-line mode.
The Site, Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Note
CSs connected to legacy gateways can be used together with IP-CSs connected to the KX-NS1000 system.
CSs connected to legacy gateways must be registered to Air Synchronization Group Number 1. Do not
register CSs connected to legacy gateways to any other Air Synchronization Group Number.
Adding CSs
Follow the steps below to add CSs to the air synchronization group.
1.
Connect the CS to be registered to the network and, if necessary, the power supply.
2.
Click Add.
A dialog box will appear. Non-registered (available) CSs are displayed on the left.
3.
Highlight CSs and click the right arrow to select them for addition.
4.
Click OK.
Deleting CSs
Follow the steps below to delete CSs from the air synchronization group.
1.
Click Delete.
A dialog box will appear. Registered CSs are displayed on the left.
2.
Highlight CSs and click the right arrow to select them for deletion.
3.
Click OK.
Air Synchronization Group Number
Select the air synchronization group to program.
Default
Not applicable
Value Range
1–16
Maintenance Console Location
19.2.1 PBX Configuration—[11-2-1] Maintenance—CS Synchronization—Air Synchronization