Note on I/O port settings:
Make sure that the following I/O ports do not overlap so
that the JOG board can perform 10-bit address
decoding.
JOG board
230H
*230-*23F *630-*63F *A30-*A3F *E30-*E3F
240H
*240-*24F *640-*64F *A40-*A4F *E40-*E4F
330H
*330-*34F *730-*73F *B30-*B3F *F30-*F3F
340H
*340-*34F *740-*74F *B40-*B4F *F40-*F4F
• Generally speaking, 0240-024F and 0F40-0F4F are
often allocated to a Sound Blaster board.
4. Insert the JOG board into the ISA slot that is the farthest
away from the CPU. At this point, insert each special
cable securely into the LTC/REF connector and the
RS422-1 connector. After positioning them, secure the
cover in place using the screws.
5. Store the screws and cover that were removed in a safe
place.
6. Turn on the power and start up WindowsNT.
7. Install the driver for JOG board.
The JOG board driver is included in the CD-ROM of the
software package. Refer to the user's manual of the
software package for details on installation. When the
software package is installed, the driver will be installed at
the same time. The setting screens for the IRQ and I/O
port will appear. Select the same value as the jumper pin
settings. When installation ends, the Setup Complete
window appears.
Select "Yes, I want to restart my computer now". (When
this is selected, is displayed.)
Finish
Click
. The computer will restart.
8. When WindowsNT has restarted, click "Start".
From Programs in the Start Menu, click "Administrative
Tools" p "Windows NT Diagnostics". The program
starts up.
Other devices
9. The Windows NT Diagnostics window appears.
Click the "Resources" label. The resource list appears.
(Refer to the diagram below)
10.Confirm that the AY-RP500 board (JOG board) IRQ, I/O
port are the same number that was set with the jumper.
"Jog" indicates the AY-RP500 board.
Note: For the following cases, modify the jumper settings
for the JOG board's IRQ and the I/O port, and reinstall
the JOG driver:
• "Jog" display cannot be found in the release list.
• THe JOGPAD and RS422 control functions do not work
with an application
The Windows NT Diagnosis