Wsw18; Selectors 2 And 3: Detection Enabled Time For Cng Or No Tone; Registration Of Station Id; Selectors 7 And 8: Tone Sound Monitoring - Brother MFC640CW Service Manual

Hide thumbs Also See for MFC640CW:
Table of Contents

Advertisement

Selector
No.
1
Not used.
2
Detection enabled time for CNG
or no tone
3
4
Not used.
5
6

Registration of station ID

7
Tone sound monitoring
8

Selectors 2 and 3: Detection enabled time for CNG or no tone

After the line is connected via the external telephone or by picking up the handset of the machine,
the machine can detect a CNG signal or no tone for the time length specified by these selectors. The
setting specified by these selectors becomes effective only when selector 8 of WSW20 is set to "1."
Selector 6:
Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and Czech models.

Selectors 7 and 8: Tone sound monitoring

These selectors set monitoring specifications of the tone sound inputted from the line.

WSW18

(Function setting 3)
Function
App. 4-21
Setting and Specifications
No. 2
3
0
0
:
40 sec.
0
1
:
0 sec. (No detection)
1
0
:
5 sec.
1
1
:
80 sec.
0:
Permitted
No. 7
8
0
X
:
No monitoring
1
0
:
Up to phase B at the
calling station only
1
1
:
All transmission phases
both at the calling and
called stations
1:
Prohibited
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcp340cwMfc820cw

Table of Contents