RUGGEDCOM RX1400
Installation Guide
Section 6.1.14

RoHS

This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of
Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic
equipment:
• China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic Information Products
A copy of the Material Declaration is available online at
view/109738831.
Section 6.1.15
Other Approvals
This device meets the requirements of the following additional standards:
• IEEE 1613
IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric
Power Substations
• IEC 61850-3
General Requirements
• IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments
• NEMA TS-2
Traffic Controller Assemblies with NTCIP Requirements
Section 6.2
EMC and Environmental Type Tests
The RUGGEDCOM RX1400 has passed the following Electromagnetic Compatibility (EMC) and environmental tests.
EMC Type Tests per IEC 61850-3
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
RoHS
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge Immunity
https://support.industry.siemens.com/cs/ww/en/
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV Line-to-Earth
Chapter 6
Certification
Severity
Levels