Caution : During assembling, ensure the Main P.C.B. is
properly seated onto the locators.
• Disassembly of Top Shield
Step 13 : Remove Top Shield.
Caution : During assembling, ensure the Top Shield is
properly seated onto the locators.
8.8.
Replacement of Top Case Unit
• Refer to "Disassembly of Bottom Case Unit"
• Refer to "Disassembly of Main P.C.B."
8.8.1.
Disassembly of Top Case Unit
Step 1 : Use Minus Screwdriver gently lift up the Shaft and
push forward as arrow shown.
Caution : During assembling, push the shaft as arow
shown a "CLICK" sound can be heard when the Shaft is
fully catched.
40