ISSUE 4.1 (R5.1)
While an Analogue Telephone (port) is ringing or MW-lamp is flashing on an
Analogue Phone (port), do not disconnect the phone from the port and or
connect another type of the terminal to this port.
3.4.2.1 Connectors
The following table shows the pin-outs for the RJ-61 cable connector for Analogue extension
connections.
8 765 4321
3.4.3 Cabling IP4WW-000E-B1
This IP4WW-000E-B1 PCB does not have any connection for cabling.
3.4.4 Cabling and Setting IP4WW-4COIDB-B1
This IP4WW-4COIDB-B1 PCB provides two RJ-61 connections for CO lines (J2) and PFT TEL (J3).
Single Line
Telephone
Hardware Manual
Table 2-10 RJ-61 Analogue Pin-Outs (J101, J102)
Pin No.
1
2
3
4
5
6
7
8
J3
PF1
T1 5
R1 4
Figure 2-70 Connectors of 4COIDB-B1
SLI 1-4 (J101), SLI 5-8 (J102): 2-Wire Analogue Exten-
sion port Connector (RJ-61)
T4 (Tip for port 4)
T3 (Tip for port 3)
T2 (Tip for port 2)
R1 (Ring for port 1)
T1 (Tip for port 1)
R2 (Ring for port 2)
R3 (Ring for port 3)
R4 (Ring for port 4)
J2
CO1-4
2-Core Cable
(Non polarity)
5 T1
4 R1
3 T2
6 R2
2 T3
7 R3
1 T4
8 R4
SL1100
Analog trunk 1
Analog trunk 2
Analog trunk 3
Analog trunk 4
2-47