[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] flow-control receive enable
flow-interval
Syntax
flow-interval interval
undo flow-interval
View
Ethernet interface view
Default level
2: System level
Parameters
interval: Sets the statistics polling interval, in seconds. It ranges from 5 to 300 and must be a multiple of
5.
Description
Use flow-interval to set the interface statistics polling interval.
Use undo flow-interval to restore the default interval.
Examples
# Set the statistics polling interval to 100 seconds on Ethernet 1/0/1.
<Sysname> system-view
[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] flow-interval 100
interface
Syntax
interface interface-type interface-number
View
System view
Default level
2: System level
Parameters
interface-type interface-number: Specifies an interface type and number.
Description
Use interface to enter interface view.
Examples
# Enter Ethernet 1/0/1 interface view (assuming that the interface is an Ethernet interface).
<Sysname> system-view
[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1]
19