Calibrating The Touch Panel - Siemens SINUMERIK 840D sl Operating Manual

Hmi sl universal
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

HT8

9.4 Calibrating the touch panel

9.4
Calibrating the touch panel
It is necessary to calibrate the touch panel upon first connection to the control.
Note
Recalibration
If the operation is not exact, then redo the calibration.
Proceed as follows
152
1.
Press the "Back" key and the "MENU SELECT" key at the same time
to start the TCU service screen.
...
2.
Touch the "Calibrate TouchPanel" button.
The calibration process will be started.
3.
Follow the instructions on the screen and touch the three calibration
points one after the other.
The calibration process has terminated.
4.
Touch the horizontal softkey "1" or the key with the number "1" to
close the TCU service screen.
Operating Manual, 11/2006, 6FC5398-6AP10-1BA0
HMI sl Universal

Advertisement

Table of Contents
loading

Table of Contents