Applicant: Motorola Solutions
394 | Expansion Options
•
X = 1 for SC1, and 2 for SC2
•
yy:yy:yy:yy:yy:yy = the MAC address of the interface. Note that eth0 and eth1 have different MAC
addresses.
7 From the prompt, run the command
spw inet/if/eth1 "dhcp:no addr:10.0.254.X mask:255.255.255.0 dev_name:tsec1
dev_unit:1 ethaddr:yy:yy:yy:yy:yy:yy mtu:1500"
•
X = 1 for SC1, and 2 for SC2
•
yy:yy:yy:yy:yy:yy = the MAC address of the interface. Note that eth0 and eth1 have different MAC addresses.
8
Configuring Site Controller IDs
Note: The Site Controllers must have different ID values configured. To check the SC id, follow the steps
below.
Procedure:
1 Log onto the Site Controller Application MMI.
2 From the SC: prompt, run the command id.
3 An id value of either A or B is displayed.
4 Perform the same check on the second Site Controller.
5 If the IDs are the same, one of the ID values have to be changed. To do so, log onto the Site Controller
Application MMI.
6 From the SC: prompt, run the command id x where x can be either A or B. Make sure to define a value different
for the two Site Controllers.
7 Reset the Site Controller.
Expansion from Two-Channel to Four-Channel Cavity Combiner
It is possible to expand from a two-channel Cavity Combiner to a four-channel Cavity Combiner.
The order of an additional Cavity Combiner is dependent on the type of Cavity Combiner existing in the current
configuration of the MTS 4 cabinet. There are type of the Cavity Combiner:
•
Auto Tune Cavity Combiner (ATCC)
•
Manual Tune Cavity Combiner (MTCC)
Note: The additional Cavity Combiner is delivered with the expansion kit that includes required equipment
and cables.
Send Feedback
| September 2014 | 6802800U74-AD
Note:
Note:
Important: Remember to check the IP settings on both SCs.
Note: It does not matter if it is the ID value of SC1 or SC2 that is changed, as long as they do not have
the same ID value.
Equipment Type: ABZ89FC5827 / 109AB-5827
Exhibit D2