Addresses Of The I/O Of Digital Modules - Siemens CPU 313C Hardware And Installation Manual

S7-300 automation system
Hide thumbs Also See for CPU 313C:
Table of Contents

Advertisement

$GGUHVVLQJ
The byte address depends on the module start address.
The bit address is the number printed on the module.
Insert the first digital module into slot 4 so that it has default start address 0. The
start address of every subsequent digital module will be incremented by 4 per slot
(see diagram under 6ORWEDVHG PRGXOH DGGUHVVLQJ 
The figure below shows you how the addresses of the individual channels of a
digital module are obtained.
Figure 8-2 Addresses of the I/O of digital modules
8-4
0
1
2
Byte address:
3
4
start address of modules
5
6
7
0
1
2
3
Byte address:
4
start address of modules + 1
5
6
7
Bit address
S7-300 Automation System, Hardware and Installation: CPU 31xC and CPU 31x