Diagnostics Status; Xstatus Diagnostics Message [N] Description; Xstatus Diagnostics Message [N] Level; Xstatus Diagnostics Message [N] References - Cisco TelePresence DX70 Reference Manual

Application programming interface
Hide thumbs Also See for TelePresence DX70:
Table of Contents

Advertisement

Cisco TelePresence DX70 and DX80
Introduction

Diagnostics status

xStatus Diagnostics Message [n] Description

Shows a description of the current diagnostics alerts.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus Diagnostics Message Description
*s DiagnosticsResult Message 1 Description: "IP configuration incomplete"
** end

xStatus Diagnostics Message [n] Level

Shows the level of importance of the diagnostics message.
Error: There is an error in the system. The system can still be used, but there can be some
restrictions.
Warning: A problem is detected and a more specific report follows indicating the exact problem.
Critical: The warning level is critical. The system cannot be used.
Requires user role: ADMIN, USER
Value space of the result returned:
Error/Warning/Critical
Example:
xStatus Diagnostics Message 4 Level
*s Diagnostics Message 4 Level: Warning
** end
D15363.05 Cisco TelePresence DX70 and DX80 API Reference Guide CE9.2, NOVEMBER 2017.
About the API
xConfiguration
xCommand

xStatus Diagnostics Message [n] References

Additional information on the diagnostics alert, if available.
Requires user role: ADMIN, USER
Value space of the result returned:
String
Example:
xStatus Diagnostics Message 10 References
*s Diagnostics Message 10 References: "delay=190"
** end
160
API Reference Guide
xStatus
xStatus
Appendices
Copyright © 2017 Cisco Systems, Inc. All rights reserved.