Precautions For Use - NEC Express 5800 Series User Manual

Bmc configuration
Hide thumbs Also See for Express 5800 Series:
Table of Contents

Advertisement

BMC Configuration User's Guide
7.

Precautions for Use

7.1
BMC Configuration installation
-- BMC Configuration Installer (Windows & Linux) can not downgrade to the older version. If you want to
use the older version, uninstall the current version and then install older version.
Note: All the registered information will be deleted as the result of the uninstalling.
-- BMC Configuration (Windows) Installer may indicate a message that requests the removable media if you
upgrade the BMC Configuration with the installer on CD-ROM/DVD-ROM. In this case, copy the
installer on the HDD and then upgrade.
7.2
HTTP / HTTPS settings
-- HTTP alone can not be set to "Enable". When HTTP is set to "Enable", HTTPS is also set to "Enable"
automatically.
7.3
Redirection setting
-- If Redirection of Management Software setting in Miscellaneous is applied to "Enable", the Value of after
rebooting of BIOS Redirection Port in BIOS Console Redirection Configuration is set to "Serial Port B".
7.4
PEF setting and SNMP Alert setting
-- If Platform Event Filter in Miscellaneous is applied to "Disable", SNMP Alert is set to "Disable". And if
SNMP Alert is applied to "Enable", Platform Event Filter is set to "Enable".
7.5
Alert form BMC
-- In the case that the item "Alert" on BMC Configuration is enabled, BMC will alert directly to the specified
alert receiver when the event specified in Alert Level is occurred. If NEC ESMPRO Manager or NEC
ESMPRO Manager Association Module is installed on the alert receiver, the SNMP alert from BMC is
registered on Alert Manager.
-- Sending the alert from BMC depends on exist of NEC ESMPRO Agent.
(1) In the case of NEC ESMPRO Agent has been installed on the managed server.
If OS does not run on the managed server, BMC send the alert when the specified event happens.
After OS runs and NEC ESMPRO Agent starts, BMC does not send the alert even if the event happens,
because NEC ESMPRO Agent sends the alert.
(2) In the case of NEC ESMPRO Agent has not been installed on the managed server.
BMC sends the alert whenever the specified event happens.
7.6
Alert Test
-- Please send a test alert after completing all the settings of the Alert Configuration. You may be unable to
use the alert function due to network environment and settings.

Advertisement