Alternate macro

This macro provides an I/O configuration adapted to a sequence of DI control
signals used when alternating the rotation direction of the drive. To enable the
macro, set the value of parameter
For the parameter default values, see section
macros
see section

Default I/O connections

1...10 kohm
Alternative connection
for AI1. If used, switch
IU selector to U
(0...10 V voltage
signal).
1)
See parameter group
DI3 DI4 Operation (parameter)
0
1
0
1
on page 65. If you use other than the default connections presented below,
I/O terminals
on page 34.
I/O connection
SCR
AI
GND
3)
+10V
+24V
GND
DCOM
DI1
DI2
DI3
DI4
DI5
Relay connection
COM
NC
NO
12 CONSTANT
0 Set speed through
integrated potentiometer
0 Speed 1 (1202)
1 Speed 2 (1203)
1 Speed 3 (1204)
9902
to 3 (ALTERNATE).
Default parameter values with different
4)
Signal cable shield (screen)
Frequency reference: 0...20 mA
Analog input circuit common
Reference voltage: +10 VDC, max. 10 mA
Auxiliary voltage output: +24 VDC, max. 200 mA
Auxiliary voltage output common
Digital input common
Start forward: If DI1 = DI2, the drive stops.
Start reverse
Constant speed selection
Constant speed selection
Acceleration and deceleration selection
5)
Relay output
No fault [Fault (-1)]
2)
SPEEDS:
0 = ramp times according to parameters
and 2203.
1 = ramp times according to parameters
and 2206.
3)
360 degree grounding under a clamp.
4)
Tightening torque = 0.22 N·m / 2 lbf. in.
5)
Tightening torque = 0.5 N·m / 4.4 lbf. in.
1)
1)
2)
Application macros
61
2202
2205