4. Understanding advanced features
4-4. Using sport meter as Exposure Index (EI) assist
Adjusting EI with percent (%) display (example)
1. Set display unit of the spot meter function.
MENU > OUTPUT SETTINGS > LCD EI ASSIST > SPOT METER UNIT > %
2. Recall the function with one of the USER buttons (USER3 in the factory setting).
3. Position the sampling box (displayed in center of the viewfinder image) over the subject to be
measured (18% gray reference for example).
4. Set the aperture, ISO, Frame rate (fps), and shutter so that the level shown on the spot meter
is 42% in "V-Log" and "V-255570L1" gamma modes, or 45% in "V-504580L1".
Adjusting EI with STOP display (example)
1. Set display unit of the spot meter function with the menu item below.
MENU > OUTPUT SETTINGS > LCD EI ASSIST > SPOT METER UNIT > SPOT
2. Recall the function with one of the USER buttons (USER3 in the factory setting).
3. Position the sampling box (displayed in center of the viewfinder image) over the subject to be
measured (18% gray reference for example).
4. Set the aperture, ISO, Frame rate (fps), and shutter so that the level shown on the spot meter
is 0.0STOP.
NOTE
* See 2-4. User assignable buttons (P.22) how to assign functions to USER buttons.
* Size of the box (zone for measurement) can be changed in MENU > OUTPUT SETTINGS
> LCD EI ASSIST > SPOT METER SIZE> S, M, L