Siemens SIMATIC Ident Operating Manual page 52

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Operating the software
5.4 The tabs of the RF620R/RF630R readers
Controlling recordings
Using the "First Tag", "Start", "Stop" and "Clear View", you can control the recording of the
transmit/radiated power:
● First Tag
● Start
● Stop
● Deleting the display
A progress bar indicates that the recording is active.
List of identified transponders
After you have started recording the transmit/radiated power, all the transponders identified
by the reader are listed in the table.
Table 5- 7
Property
Tag ID
Antenna
RSSI
Cycles
Count
Time
Time since Start The time in [ms] that has elapsed since the start of the test and the first successful
The color in the table row indicates whether or not the transponder was identified during the
last inventories:
Green
Light green
Red
The sum of the identified transponders is displayed in the "Identified Tags" output box.
52
Cyclic reads are triggered on the selected antenna and the measured values obtained
are displayed. The recording is stopped automatically when a transponder is identified
the first time.
Any existing values from a previous recording are deleted. A new recording is then
started. Reads of the selected antenna are performed cyclically.
Stopping the recording
Existing values from the last recording are deleted.
Displayed properties of the recognized transponders
Description
EPC ID of the detected transponder
Antenna with which the transponder was detected. Only one antenna is ever
displayed here. With this display, you cannot recognize the antenna or antennas
that detected the transponder or whether several antennas detected the
transponder.
RSSI value with which the transponder was last read.
Number of inventories since this transponder was identified the first time
Number of successful inventories of this transponder.
Time stamp when the transponder was last read.
read of the transponder.
Transponder was identified during the last inventory
Transponder was not identified only during the last inventory
Transponder was not identified during the last two inventories
Operating Manual, 09/2012, C79000-G8976-C292-01
SIMATIC RF-DIAG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf-diag

Table of Contents