The "VSWR" tab

With the "VSWR" tab, you can read out HF values, quality characteristics of the air interface.
Figure 5-14
The HF Values
Parameter
VSWR
Tx Power
Rx Power
Noise Level
*) A value ≥ 1.5 may indicate a hardware defect. Contact Customer Support in this case.
From the upper drop-down list, you can select the antenna with which you want to read out
the HF values. From the lower drop-down list, you can select the frequency range of the
antenna. If the frequency you require cannot be selected, you can also enter this value. You
will find the frequency bands of the various reader types in the following table:
62
The "VSWR" tab
Description
Voltage standing wave ratio: Is calculated from Tx and Rx Power. *
Power at output in [dBm]
Power at input in [dBm]
Noise level: Wideband RSSI value measured by reader