Battery Installation And Replacement; Installing The Battery; Replacing The Battery - Mitsubishi Electric MES3-255C-DM-EN User Manual

Energy saving data collecting server ecowebserveriii
Table of Contents

Advertisement

6. Battery Installation and Replacement(Server section)
6.1
Installing the battery(Server section)
The battery is shipped with the battery connector removed. Before use, make sure to connect the battery connector.
(1) Open the battery cover on the bottom of the server.
(2) Check that the battery is properly installed.
(3) Insert the connector on the battery into the case-side
connector pin, observing the correct orientation.
6.2
Replacing the battery(Server section)
When the battery reaches its end of life, the "ERR." LED on the server section turns red. Replace the battery with a new
one. (See "11 Options.")
(1) Open the front cover on the server section, and set the
RESET switch to the SEL position.
(2) When the "CF CARD" LED turns off, turn the product off.
(3) Open the battery cover on the bottom of the server section.
(4) Remove the battery from the holder.
(5) Insert a new battery into the holder in the correct orientation
and connect the lead connector to the connector.
(6) Close the battery cover.
(7) Turn the product on.
Cautions
Connector
(main unit side)
Connector
(battery side)
 Make sure to perform battery replacement with power turned off.
 Complete battery replacement within 3 minutes. If 3 minutes passes with the battery
removed, the data for the last 1 hour and the clock setting may be initialized. (The data and
setting values older than those for the last 1 hour are not initialized.)
If the IP address and clock settings are initialized, reconfigure those settings after backing
up the data.
Make bundles of excess lengths of lead wire
on the top of the battery (inside the main unit)
as shown below.
Connector
Connector
(main unit side)
Connector
(battery side)
23
Battery
lead wire
Connector stopper
Battery

Advertisement

Table of Contents
loading

Table of Contents