Replacing The Backup Battery - Mitsubishi Electric FT5000 Handbook

Ft series
Table of Contents

Advertisement

M a i n b o a r d

Replacing the backup battery

The lithium battery on the baseboard powers the real-time clock (RTC) for three to four years in
the absence of power. When the battery weakens, it loses voltage and the system settings stored in
CMOS RAM in the RTC (e.g. the date and time) may be wrong.
C C A A U U T T I I O O N N
Replace only with the same or equivalent type recommended by your Mitsubishi Electric supplier.
Discard used batteries strictly according to the battery manufacturer's instructions.
1.
Read through the instructions on page 4 of this chapter.
2.
Remove the access cover, for detailed instructions see Chapter 2.
3.
Insert the tip of a small non-metallic under the plastic tab on the snap-on plastic retainer.
W W A A R R N N I I N N G G
You must not use a metal or other conductive implement to remove the battery. If a short-circuit is
accidentally made between the battery's positive and negative terminals, the battery may explode.
4.
Gently push down on the tool to lift the battery.
5.
Remove the battery from its socket.
6.
Remove the new lithium battery from its package and, being careful to observe the correct
polarity, insert it in the battery socket.
7.
Reinstall the plastic retainer on the lithium battery socket.
8.
Reinstall the access cover using the original screws.
9.
Run the SSU to restore the configuration settings to the RTC.
5/16
FT5000 HANDBOOK
B
A
C

Advertisement

Table of Contents
loading

Table of Contents