Mitsubishi Electric A800 Plus Series Function Manual page 17

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Parameter list (by parameter number)
Pr.
Pr.
group
269
E023
Parameter for manufacturer setting. Do not set.
Acceleration/deceleration time
270
R342
during stall condition
Second acceleration time for
271
R537
inertia compensation
Second deceleration time for
272
R538
inertia compensation
276
R400
Line speed monitoring reference 0 to 6553.4 m/min
Actual line speed voltage/
278
R051
current gain
279
R052
Actual line speed gain
Actual line speed voltage/
280
R053
current bias
281
R054
Actual line speed bias
Actual line speed pulse input
282
R055
bias
Actual line speed pulse input
283
R056
gain
Actual line speed input filter
284
R057
time constant
A107
Overspeed detection frequency
285
Speed deviation excess
H416
detection frequency
286
G400
Droop gain
287
G401
Droop filter time constant
Droop function activation
288
G402
selection
289
M431
Inverter output terminal filter
Monitor negative output
290
M044
selection
291
D100
Pulse train I/O selection
294
A785
UV avoidance voltage gain
Frequency change increment
295
E201
amount setting
296
E410
Password lock level
297
E411
Password lock/unlock
298
A711
Frequency search gain
Rotation direction detection
299
A701
selection at restarting
RS-485 communication station
331
N030
number
332
N031
RS-485 communication speed
RS-485 communication stop bit
length / data length
RS-485 communication data
333
N032
length
RS-485 communication stop bit
N033
length
RS-485 communication parity
334
N034
check selection
RS-485 communication retry
335
N035
count
RS-485 communication check
336
N036
time interval
RS-485 communication waiting
337
N037
time setting
Communication operation
338
D010
command source
16
PARAMETER LIST
Name
Setting range
0 to 3600 s
0 to 3600 s
0 to 3600 s
0 to 100%, 9999
0 to 6553.4 m/min
9999
0 to 100%, 9999
0 to 6553.4 m/min
9999
0 to 500, 9999
0 to 500, 9999
0 to 5 s
0 to 30 Hz, 9999
0 to 100%
0 to 1 s
0, 1, 2, 10, 11, 20 to 22
5 to 50 ms, 9999
0 to 7
[FM type]
0, 1, 10, 11, 20, 21, 100
[AM type]
0, 1
0 to 200%
0, 0.01, 0.10, 1.00, 10.00
0 to 6, 99, 100 to 106,
199, 9999
(0 to 5), 1000 to 9998,
9999
0 to 32767, 9999
0, 1, 9999
0 to 31 (0 to 247)
3, 6, 12, 24, 48, 96, 192,
384, 576, 768, 1152
0, 1, 10, 11
0, 1
0, 1
0 to 2
0 to 10, 9999
0 to 999.8 s, 9999
0 to 150 ms, 9999
0, 1
Minimum
Initial value
setting
FM
increments
0.1 s
15 s
0.1 s
15 s
0.1 s
15 s
0.1 m/min
1000 m/min
∗11
∗11
0.1%
9999
,
∗11
0.1 m/min
9999
∗11
0.1%
9999
,
∗11
0.1 m/min
9999
∗11
0.01
9999
0.01
9999
0.01 s
0.02 s
0.01 Hz
9999
0.1%
0%
0.01 s
0.3 s
1
0
1 ms
9999
1
0
1
0
0.1%
100%
0.01
0
1
9999
1
9999
1
9999
1
0
1
0
1
96
1
1
1
0
1
1
1
2
1
1
0.1 s
0 s
1 ms
9999
1
0
Refer
Customer
to
CA
setting
page
137
130
130
186
∗11
163
163
163
163
163
163
163
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
193

Advertisement