Parameter list (by parameter number)
Pr.
Pr.
group
PLC function operation
414
A800
selection
Inverter operation lock mode
415
A801
setting
416
A802
Pre-scale function selection
417
A803
Pre-scale setting value
422
B003
Position control gain
Dancer / tension sensor
423
R422
feedback detection level
Dancer / tension sensor
424
R104
feedback input offset
425
R160
Break detection waiting time
426
R412
Dancer tension setting bias
427
R413
Dancer tension setting gain
428
B009
Command pulse selection
430
R410
Dancer tension setting
432
Pulse train torque command
D120
bias
∗9
433
Pulse train torque command
D121
gain
∗9
450
C200
Second applied motor
Second motor control method
451
G300
selection
453
C201
Second motor capacity
454
C202
Number of second motor poles
455
C225
Second motor excitation current
456
C204
Rated second motor voltage
457
C205
Rated second motor frequency
458
C220
Second motor constant (R1)
459
C221
Second motor constant (R2)
460
C222
Second motor constant (L1)
461
C223
Second motor constant (L2)
462
C224
Second motor constant (X)
Second motor auto tuning
463
C210
setting/status
PID proportional band for values
464
R113
below set point
PID integral time for values
465
R114
below set point
PID differential time for values
466
R115
below set point
467
R116
Second PID proportional band
468
R117
Second PID integral time
469
R118
Second PID differential time
Second PID proportional band
470
R119
for values below set point
Second PID integral time for
471
R120
values below set point
Second PID differential time for
472
R121
values below set point
473
R122
Third PID proportional band
474
R123
Third PID integral time
18
PARAMETER LIST
Name
Setting range
0 to 2, 11, 12
0, 1
0 to 5
0 to 32767
0 to 150 sec
0 to 100%
400 to 600%
0 to 100 s, 9999
0 to 200%
0 to 200%
0 to 5
1 to 100, 9999
0 to 400%
0 to 400%
0, 1, 3 to 6, 13 to 16, 20,
23, 24, 30, 33, 34, 40, 43,
44, 50, 53, 54, 70, 73, 74,
9999
10 to 12, 20, 110 to 112,
9999
0.4 to 55 kW, 9999
0 to 3600 kW, 9999
2, 4, 6, 8, 10, 12, 9999
0 to 500 A, 9999
0 to 3600 A, 9999
0 to 1000 V
10 to 400 Hz, 9999
0 to 50 Ω, 9999
0 to 400 mΩ, 9999
0 to 50 Ω, 9999
0 to 400 mΩ, 9999
0 to 6000 mH, 9999
0 to 400 mH, 9999
0 to 6000 mH, 9999
0 to 400 mH, 9999
0 to 100%, 9999
0, 1, 11, 101
0.1 to 1000%, 9999
0.1 to 3600 s, 9999
0.01 to 10 s, 9999
0.1 to 1000%, 9999
0.1 to 3600 s, 9999
0.01 to 10 s, 9999
0.1 to 1000%, 9999
0.1 to 3600 s, 9999
0.01 to 10 s, 9999
0.1 to 1000%, 9999
0.1 to 3600 s, 9999
Minimum
setting
increments
1
1
1
1
-1
-1
1 sec
0.01%
0.01%
0.01 s
0.1%
0.1%
1
0.1
1%
1%
1
1
0.01 kW
∗2
∗2
0.1 kW
∗3
∗3
1
0.01 A
∗2
∗2
0.1 A
∗3
∗3
0.1 V
0.01 Hz
0.001 Ω
∗2
∗2
0.01 mΩ
∗3
∗3
0.001 Ω
∗2
∗2
0.01 mΩ
∗3
∗3
0.1 mH
∗2
∗2
0.01 mH
∗3
∗3
0.1 mH
∗2
∗2
0.01 mH
∗3
∗3
0.1%
0.01%
1
0.1%
0.1 s
0.01 s
0.1%
0.1 s
0.01 s
0.1%
0.1 s
0.01 s
0.1%
0.1 s
Initial value
Refer
Customer
to
FM
CA
setting
page
0
∗17
0
∗17
0
∗17
1
∗17
-1
25 sec
∗17
73,
10%
107
73,
500%
108
74,
9999
108,
150
0%
92
100%
92
0
60
100
92
0%
∗18
150%
∗18
9999
∗17
9999
5
9999
∗17
9999
∗17
9999
∗17
200 V
∗7
∗17
400 V
∗8
9999
∗17
9999
∗17
9999
∗17
9999
∗17
9999
∗17
9999
∗17
0
∗17
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86