Parameters (functions) and instruction codes under different control methods

10.5
Parameters (functions) and instruction
codes under different control methods
The following parameters and instruction codes are changed or added in the FR-A800-R2R inverter as compared to the FR-
A800 series standard inverter. The availability of the parameters and instruction codes is shown by control method.
For information on the availability of other parameters by control method and instruction codes, refer to the Instruction Manual
(Detailed) of the FR-A800 inverter.
∗1
Instruction codes are used to read and write parameters by using the Mitsubishi inverter protocol via RS-485 communication.
(For the details of the RS-485 communication, refer to the Instruction Manual (Detailed) of the FR-A800 inverter.)
∗2
Function availability under each control method is as follows:
: Available
×: Not available
Δ: Available with some restrictions
∗3
For "parameter copy", "parameter clear", and "all parameter clear", "" indicates the function is available, and "×" indicates the function is not
available.
∗4
Communication parameters that are not cleared by parameter clear or all clear (H5A5A or H55AA) via communication.
∗5
When a communication option is installed, parameter clear (lock release) during password lock (Pr.297 Password lock/unlock ≠ "9999") can
be performed only from the communication option.
∗6
Reading and writing via the PU connector are available.
∗7
The parameter is used for gain adjustment during serve lock.
∗8
Available under tension sensor feedback torque control.
The function of the parameter with the following mark is available when the option is connected.
FR-A8AP,
FR-A8AL,
FR-A8TP,
FR-A8NC,
FR-A8NCE,
FR-A8ND,
Pr.
Name
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
DC injection brake operation
10
frequency
11
DC injection brake operation time
12
DC injection brake operation voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High speed maximum frequency
19
Base frequency voltage
Acceleration/deceleration reference
20
frequency
Acceleration/deceleration time
21
increments
Stall prevention operation level
22
?Torque limit level?
Stall prevention operation level
23
compensation factor at double speed
24
Multi-speed setting (speed 4)
FR-A8APR,
FR-A8APS,
FR-A8AR,
FR-A8NP
Instruction
code
∗1
00
80
0
01
81
0
02
82
0
03
83
0
04
84
0
05
85
0
06
86
0
07
87
0
08
88
0
09
89
0
0A
8A
0
0B
8B
0
0C
8C
0
0D
8D
0
0E
8E
0
0F
8F
0
10
90
0
11
91
0
12
92
0
13
93
0
14
94
0
15
95
0
16
96
0
17
97
0
18
98
0
FR-A8AX,
FR-A8AY,
Control method
∗2
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
FR-A8AZ,
Parameter
217
APPENDIX
10