Dancer feedback speed control details
Dancer signal input selection (Pr.363)
• Use Pr.363 Dancer / tension sensor feedback input selection to select the input terminal for the dancer signal
(measured value).
Pr.363 setting
3
Terminal 2 (0 to 100%) (0 to 5 V)
4
Terminal 4 (20 to 100%) (4 to 20 mA)
5 (initial value)
Terminal 1 (-100 to 100%) (-10 to 10 V)
6
Terminal 6 (FR-A8AZ) (-100 to 100%) (-10 to 10 V)
Dancer signal calibration example
• The following parameters are used for calibrating the dancer signal according to the input terminal. The dancer signal
analog input values at both 0% and 100% can be calibrated.
Input terminal
Terminal 2 (0 to 100%)
Terminal 4 (0 to 100%)
∗1
Terminal 1 (-100 to 100%)
Terminal 6 (FR-A8AZ) (-100 to 100%)
∗1
The initial input range is 20 to 100%.
• In the following example, a potentiometer with the output range of -10 to 10 V is used for inputting the dancer signal to
terminal 1 (input range: -10 to 10 V). The neutral position is defined as 0% for the calibration. C13 (Pr.917) Terminal 1 bias
(speed) and C15 (Pr.918) Terminal 1 gain (speed) are used for calibration.
• In the following example, a potentiometer with the output range of 1 to 7 V is used for inputting the dancer signal to terminal
2 (input range: 0 to 10 V). The neutral position is defined as 0% for the calibration. C3 (Pr.902) Terminal 2 frequency
setting bias and C4 (Pr.903) Terminal 2 frequency setting gain are used for calibration.
72
DANCER FEEDBACK SPEED CONTROL
Input terminal
C3 (Pr.902), C4 (Pr.903)
C6 (Pr.904), C7 (Pr.905)
C13 (Pr.917), C15 (Pr.918)
C31 (Pr.926), C33 (Pr.927)
Potentiometer
-10 to 10 V
Potentiometer
1 to 7 V
Calibration parameter
Dancer signal
100%
-10 V
Calibration example
(initial value)
Terminal 1 calibration example
Dancer signal
Calibration example
100%
1 V
0
4 V
C3 (Pr.902)
-100%
Terminal 2 calibration example
0
10 V
C15 (Pr.918)
C13 (Pr.917)
Analog input value
-100%
Analog
7 V
10 V
input value
C4 (Pr.903)