Mitsubishi Electric A800 Plus Series Function Manual page 37

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Parameter list (by function group)
Pr.
Pr.
group
H620
148
Stall prevention level at 0 V input
H621
149
Stall prevention level at 10 V input ─
Voltage reduction selection
H631
154
during stall prevention operation
Torque limit input method
H700
810
selection
H701
812
Torque limit level (regeneration)
H702
813
Torque limit level (3rd quadrant)
H703
814
Torque limit level (4th quadrant)
H704
801
Output limit level
H710
815
Torque limit level 2
Torque limit level during
H720
816
acceleration
Torque limit level during
H721
817
deceleration
H730
874
OLT level setting
H800
374
Overspeed detection level
H881
690
Deceleration check time
M: Monitor display and monitor
output signal
Parameters regarding the inverter's operating status. These
parameters are used to set the monitors and output signals.
Pr.
Pr.
group
M000
37
Speed display
M001
505
Speed setting reference
M002
144
Speed setting switchover
M020
170
Watt-hour meter clear
Energization time carrying-over
M021
563
times
M022
268
Monitor decimal digits selection
Cumulative power monitor digit
M023
891
shifted times
M030
171
Operation hour meter clear
Operating time carrying-over
M031
564
times
M040
55
Frequency monitoring reference
M041
56
Current monitoring reference
M042
866
Torque monitoring reference
Analog input display unit
M043
241
switchover
M044
290
Monitor negative output selection
M045
1018
Monitor with sign selection
M050
1106
Torque monitor filter
M051
1107
Running speed monitor filter
M052
1108
Excitation current monitor filter
Control circuit temperature signal
M060
663
output level
Operation panel main monitor
M100
52
selection
Operation panel monitor
M101
774
selection 1
Operation panel monitor
M102
775
selection 2
Operation panel monitor
M103
776
selection 3
Operation panel setting dial push
M104
992
monitor selection
M200
892
Load factor
36
PARAMETER LIST
Refer
Name
to
page
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
Refer
Name
to
page
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
181
181
181
181
181
∗6
Pr.
Pr.
group
Energy saving monitor reference
M201
893
(motor capacity)
Control selection during
M202
894
commercial power-supply
operation
Power saving rate reference
M203
895
value
M204
896
Power unit cost
Power saving monitor average
M205
897
time
Power saving cumulative monitor
M206
898
clear
Operation time rate (estimated
M207
899
value)
FM/CA terminal function
M300
54
selection
M301
158
AM terminal function selection
C0
M310
(900)
FM/CA terminal calibration
∗2
C1
M320
(901)
AM terminal calibration
∗2
M321
867
AM output filter
C8
M330
(930)
Current output bias signal
∗2
C9
M331
(930)
Current output bias current
∗2
C10
M332
(931)
Current output gain signal
∗2
C11
M333
(931)
Current output gain current
∗2
M334
869
Current output filter
M400
190
RUN terminal function selection
M401
191
SU terminal function selection
M402
192
IPF terminal function selection
M403
193
OL terminal function selection
M404
194
FU terminal function selection
M405
195
ABC1 terminal function selection
M406
196
ABC2 terminal function selection
M430
157
OL signal output timer
M431
289
Inverter output terminal filter
Output current detection signal
M433
166
retention time
M440
870
Speed detection hysteresis
M441
41
Up-to-frequency sensitivity
M442
42
Output frequency detection
Output frequency detection for
M443
43
reverse rotation
Second output frequency
M444
50
detection
M445
116
Third output frequency detection
M446
865
Low speed detection
M460
150
Output current detection level
Output current detection signal
M461
151
delay time
M462
152
Zero current detection level
M463
153
Zero current detection time
Refer
Name
to
page
∗6
∗6
∗6
∗6
∗6
∗6
∗6
92,
181
92,
181
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
191
191
191
191
191
191
191
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6
∗6

Advertisement

Table of Contents
loading

Table of Contents