Lists Of Signals For The Operation Screen - Siemens SINAMICS S120 Operating Instructions Manual

Cabinet modules operator panel (option k08)
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

4.6.4.1

Lists of signals for the operation screen

The following tables list the factory default settings of the signals for the operation screen
along with the associated reference variables and default settings for quick commissioning.
Object B_INF
Table 4- 1
List of signals for the operation screen - object B_INF
Signal
DC-link voltage smoothed
Temperature of power unit
Normalization for object B_INF
Table 4- 2
Normalization for object B_INF
Variable
Reference voltage
Reference temperature
Figure 4-10
Cabinet Modules Operator Panel AOP30
Operating Instructions, 04/2014, A5E03263551A
Factory setting (entry no.)
(1)
(2)
Normalization parameters
100% = p2001
100% = 100 °C
Operation screen - example of infeed via a Basic Line Module
Parameter
Short name
r0026
U_DC
r0037
T_LT
Default for quick commissioning
p2001 = r0206/r0207
Control via the operator panel
4.6 Menu commissioning / service
Unit
Normalization (100%=...)
see table below
V
p2001
° C
p2006
47