Table 8-4 Input terminal functions
Parameter setting
Positive
Negative
logic
logic
No function
1
F: Forward run command
2
3
4
5
R: Reverse run command
6
7
ST: Standby
RES: Reset command
8
9
11 SS1: Preset-speed command 1
10
12
13 SS2: Preset-speed command 2
15 SS3: Preset-speed command 3
14
17 SS4: Preset-speed command 4
16
18
19 Jog run mode
20
21 Emergency stop by external signal
22
23 DC braking command
24
25 2nd acceleration/deceleration
27 3rd acceleration/deceleration
26
29 2nd V/F control switching
28
33 2nd stall prevention level
32
37 PID control prohibition
36
47 External thermal error input
46
49 Forced local from communication
48
Operation hold
50
51
(hold of 3-wire operation)
52
53 PID integral/differential clear
55 PID characteristics switching
54
57 Forced run operation
56
59 Fire speed operation
58
Acceleration/deceleration suspend
60
61
signal
63 Power failure synchronized signal
62
65 My function-S trigger signal
64
71 Factory specific coefficient (Note1)
70
Integrating wattmeter(kWh) display
74
75
clear
76
77 Trace back trigger signal
Light-load high-speed operation
78
79
prohibitive signal
81 Holding of RY-RC terminal output
80
83 Holding of OUT terminal output
82
Note1: Do not set the value. The function is for manufactuer setting.
Function
- 30 -
Parameter setting
Positive
Negative
logic
logic
89 Frequency UP
88
91 Frequency DOWN
90
92
93 Clear frequency UP/DOWN
96
97 Coast stop command
99 Forward/reverse selection
98
Run/stop command
100
101
Frequency setting mode forced
104
105
switching
Frequency setting mode terminal block
106
107
Command mode terminal block
108
109
110
111
Parameter editing permission
120
121
Fast stop command 1
122
123
Fast stop command 2
134
135
Traverse permission signal
Low voltage operation signal
Forward deceleration
Forward stop
142
143
Reverse deceleration
144
145
Reverse stop
146
147
Factory specific coefficient (Note1)
148
149
Factory specific coefficient (Note1)
150
151
No.2 motor switching
(AD2+VF2+OCS2)
Reset Command 2
Parameter editing prohibition
200
201
Parameter reading prohibition
202
203
E6581865
Function